EasyManuals Logo
Home>Cisco>Switch>Unified Access CT5760

Cisco Unified Access CT5760 Command Reference Guide

Cisco Unified Access CT5760
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Queried: 2 Responded: 2 Time: 0.7 seconds
DomainMember# energywise query importance 900 name Fa1.0.4* sum usage
EnergyWise query, timeout is 6 seconds:
Total Usage
-----------
129.0 (W)
Queried: 10 Responded: 10 Time: 0.6 seconds
This example shows the summary of the delta values and the potential power change in the domain:
DomainMember# energywise query importance 90 name * collect delta
EnergyWise query, timeout is 6 seconds:
Level Label Delta Power (W)
----- ----- -----------
0 Shut -12.9
1 Hibernate +723.8
2 Sleep +723.8
3 Standby +723.8
4 Ready +723.8
5 Low +723.8
6 Frugal +723.8
7 Medium +723.8
8 Reduced +723.8
9 High +723.8
10 Full +723.8
Queried: 48 Responded: 48 Time: 0.15 seconds
These examples show how to change the power level of all the domain members and endpoints.
DomainMember# energywise query importance 90 name * set level 0
EnergyWise query, timeout is 6 seconds:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Success rate is (48/48) setting entities
Queried: 48 Responded: 48 Time: 0.996 seconds
DomainMember# energywise query importance 90 name * set level 10
EnergyWise query, timeout is 6 seconds:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Success rate is (48/48) setting entities
Queried: 48 Responded: 48 Time: 0.996 seconds
These examples show how to filter results with keywords.
DomainMember(config)# interface gigabitethernet0/2
DomainMember(config-if)# energywise keywords lobby,sattelite
DomainMember(config-if)# energywise keywords public
DomainMember(config-if)# end
DomainMember# show running-config interface gigabitethernet0/2
interface GigabitEthernet0/2
energywise level 0 recurrence importance 90 at 0 8 * * *
energywise level 10 recurrence importance 90 at 0 20 * * *
energywise importance 50
energywise role role.lobbyaccess
energywise keywords lobby,sattelite,public
energywise name lobbyInterface.2
DomainMember# end
DomainMember# energywise query importance 90 keyword lobby collect usage
EnergyWise query, timeout is 6 seconds:
Host Name Usage Level Imp
---- ---- ----- ----- ---
2.2.4.30 lobbyInterface.17 15.4 (W) 10 1
2.2.5.30 pc.1 200.0 (W) 8 85
2.2.6.30 pc.2 200.0 (W) 8 85
Queried: 3 Responded: 3 Time: 1.1 seconds
DomainMember# energywise query importance 90 keyword lobby sum usage
EnergyWise query, timeout is 6 seconds:
Total Usage
-----------
415.4 (W)
Cisco EnergyWise Cisco IOS Command Reference for Catalyst 3850 Switches, EnergyWise Version 2.8
20 OL-32343-01
EnergyWise Commands
energywise query

Other manuals for Cisco Unified Access CT5760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Unified Access CT5760 and is the answer not in the manual?

Cisco Unified Access CT5760 Specifications

General IconGeneral
BrandCisco
ModelUnified Access CT5760
CategorySwitch
LanguageEnglish

Related product manuals