snmp-server enable traps energywise
To enable the domain member to send Simple Network Management Protocol (SNMP) notifications for
EnergyWise traps or inform the network management system (NMS) of requests, use the snmp-server enable
traps energywise global configuration command. To return to the default setting, use the no form of this
command.
snmp-server enable traps energywise[event-occurred][ level-change][neighbor-added][neighbor-deleted]
no snmp-server enable traps energywise[event-occurred][
level-change][neighbor-added][neighbor-deleted]
Syntax Description
(Optional) Enables EnergyWise event traps.event-occurred
(Optional) Enables EnergyWise power-level change traps.level-change
(Optional) Enables EnergyWise traps when neighbors are added.neighbor-added
(Optional) Enables EnergyWise traps when neighbors are removed.neighbor-deleted
Command Default
The sending of EnergyWise traps is disabled.
Command Modes
Global configuration
Command History
ModificationFirst EW
Version
Release
This command was introduced.2.8Cisco IOS XE 3E
Usage Guidelines
Use the snmp-server host global configuration command to specify the host (Network Management System
[NMS]) that receives the traps.
If you do not specify any keywords, all the EnergyWise traps are enabled.
You can verify your setting by entering the show energywise or the show running-config privileged EXEC
command.
Examples
This example shows how to enable the EnergyWise domain member to send traps to the NMS:
DomainMember(config)# snmp-server enable traps energywise
Cisco EnergyWise Cisco IOS Command Reference for Catalyst 3850 Switches, EnergyWise Version 2.8
OL-32343-01 29
EnergyWise Commands
snmp-server enable traps energywise