4 XML Print / Peripheral Device Control Function
40
6-2-1. Media Converter
Item Initial value Configurable
range
Description
VCOM Convert Disable Enable
Disable
Set Ena
ble when using a display or
scanner using OPOS without XML
control.
HID Scanner Convert Disable Enable
Disable
Set Enable when using a scanner in
HID mode without XML control.
Show Configuration Unselected Selected
Unselected
If you select this, the advanced
settings for communication with the
device are displayed. The initial value
of each item is the value for the
corresponding device so there is no
need to change it.
6-2-2. XML Print
Item Initial
value
Configurable
range
Description
Port Number 8080 1025 - 65535 Connection port number
Timeout for connect 10 5 - 60 Timeout time to wait for printing to start
Timeout for print 60 10 - 600
Timeout period for waiting for printer
processing completion
6-2-3. XML Device Control
Configure the following general settings for XML Device Control Service.
Item Initial
value
Configurable
range
Description
Port Number 8085 1025 - 65535 Connection port number
Timeout for connect 10 5 - 180 Timeout time to wait for control to start
(sec.)
Max Connections 2 1 - 3 Maximum numb
er of simultaneous
connections (normally use with the
initial value)