Hydraulic / Electric System LINER TIC
4-16 10/04
1.3.2 Emergency
program
The emergency program could be used when one angle transmitter fails.
Switching on: Press key 3 (working position) and key 5 (increase front swath width)
simultaneously for 7 seconds.
Notes:
• The emergency program goes through the different functions during
the period previously stored. This cannot be changed.
(Basic setting, rotor height adjustment and time adjustment on the
turning are not possible).
• Switching back and forth between the “Raise front rotors” and “Lower
front rotors” functions is not possible.
• The functions “Fold rotors to working position” and “Fold rotors to
transport position” must always be completed. When one process is
stopped by the STOP key, it must be repeated in order to reach the
desired position.
• After shutting down the control unit, it will resume normal operation
when switching it on the next time. The emergency program must
now be re-started.