ECONOMY SWITCH
When the economy control switch is
turned on, the engine speed varies
according to the load connected.
This results in decreased fuel
consumption and less noise.
When the economy control switch is
turned off, the engine runs at the
5,500 r/min. regardless of whether
there is a load connected or not.
INDICATOR LIGHTS
PILOT LIGHT
The pilot light (Green) will remain on
during normal operat
ion.
OVERLOAD INDICATOR
The overload indicator (Red) will light
up if there is an overload (in excess of
1kva) or a short circuit in the
connected appliance.
If this happens, proceed as follows:
1. Turn off any connected electrical devices and stop the engine.
2. Reduce the total wattage of connect
ed electric devices w
ithin the
application range.
3. Check air inlet and around the control unit. If any blockages are found,
remove them.
4. After checking, r
estart the engine.
LOW OIL INDICATOR
The oil indicator will light up when the oil level is low. See page 9.
CAUTION: THE ECONOMY CONTROL DOES NOT WORK EFFECTIVELY IF
THE ELECTRICAL APPLIANCE REQUIRES ‘BURSTS’ OF POWER.
CAUTION: TURN THE ECONOMY CONTROL FEATURE OFF WHEN
CONNECTING HIGH LOAD APPLIANCES OR WHEN CONNECTING TO THE
DC OUTPUT.