CleanSpace Respirators USER INSTRUCTIONS
20
English
WARNING
A negative pressure seal check must be performed in order to ensure that the test port plug is fitted
correctly after use of the on-board fit test ports. Refer to section 9, Step 4.
WARNING
Using the Full Face Mask with the rain cover raised can cause the exhalation valve to vibrate, which
may cause a buzzing noise. For correct operation, the rain cover should be lowered.
No PAPR can fully protect you if you are not clean shaven. CleanSpace Respirator is not suitable for users with facial hair.
Once you have achieved an acceptable mask fit and confirmed it with a quantitative fit test, record your information in the
table below.
Name
Mask Type
Neck Support
N/A
Date of Quantitative Fit Test
Fit Factor on Test
IF A SATISFACTORY FIT FACTOR CANNOT BE ACHIEVED WITH ANY OF THE MASKS, THE CLEANSPACE RESPIRATOR MUST NOT
BE USED.
USING THE CLEANSPACE RESPIRATOR WITH FULL FACE MASK
Complete the following steps each time you use CleanSpace Respirator with FULL FACE MASK.
Prior to entering a potentially contaminated area, the following inspection must be performed.
STEP 1 INSPECT THE CLEANSPACE RESPIRATOR
Visually inspect all the CleanSpace Respirator components, (Power Unit, mask, harness, filter adaptor, and filter). If any
components are missing or damaged, replace them only with approved CleanSpace Respirator parts before proceeding.
Check the top and bottom case of the Power Unit, and the Filter Adaptor (if fitted) for cracks or other damage. Do not use
the CleanSpace Respirator if there is any damage.
Remove the filter and inspect it carefully. The seal must be clean, and free from damage of any kind. If necessary, the seal
and housing can be cleaned with a cloth dampened with water. (The filter media must not be exposed to water). Inspect
the surfaces behind the filter carefully for any sign that dust has leaked past a damaged seal. If dust is found, replace the