Tranquility
®
30
(TT) Series
Models TTD/H/V 026 - 072
60 Hz - HFC-410A
INSTALLATION, OPERATION,
& MAINTENANCE
97B0075N05
Revised: 18 July, 2013
Table of Contents
Model Nomenclature 3
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
Electrical - Line Voltage 20
Electrical - Power Wiring 22
Electrical - Power & Low Voltage Wiring 23
Electrical - Low Voltage Wiring 24
Electrical - Thermostat Wiring 26
Blower Performance Data 27
ECM Blower Control 28
Typical Wiring Diagram - Units with CXM Board
and ECM Fan Motor (Single Phase) 30
Typical Wiring Diagram - Units with
ClimaDry
®
(Single Phase) 31
Typical Wiring Diagram - Units with CXM Board, 32
ECM Fan Motor, and MPC (DDC) CONTROLS
(SINGLE PHASE) 32
CXM Controls 33
DXM Controls 34
Safety Features - CXM and DXM Controls 36
ClimaDry
®
Modulating Reheat Option 38
Unit Starting and Operating Conditions 41
Piping System Cleaning and Flushing 42
Unit and System Checkout 44
Unit Start-Up Procedure 45
ClimaDry
®
II Option Corrections
(When Operating in Non-ClimaDry
®
Mode) 46
Unit Operating Conditions 47
Preventive Maintenance 49
Functional Troubleshooting 50
Performance Troubleshooting 51
Start-Up Log Sheet 52
Functional Troubleshooting 53
Warranty (U.S. & Canada) 54
Warranty (International) 55
Revision History 56

Questions and Answers

  • A
    Alexander VincentSep 14, 2025
    What does Swapped Thermistor Code 9 mean on my ClimateMaster Heat Pump?
    • J
      Jose MaciasSep 14, 2025
      If your ClimateMaster Heat Pump displays Swapped Thermistor Code 9, it means that LT1 and LT2 thermistors are swapped. To resolve this, reverse the position of the thermistors.
  • A
    Amber YatesNov 19, 2025
    What to do if my ClimateMaster Tranquility TTD049 shows HP Fault Code 2 High Pressure?
    • M
      Michael YoungNov 19, 2025
      If your ClimateMaster Heat Pump displays the HP Fault Code 2 indicating high pressure, it could be due to several reasons: * Reduced or no water flow in cooling: Check pump or valve operation/setting and adjust the water flow to the proper rate. Also bring the water temperature within the design parameters. * Reduced or no air flow in heating: Inspect and clean or replace the air filter. Check the fan motor operation and look for air flow restrictions. Ensure the air coil is clean and the external static isn't too high. Also bring the return air temperature within design parameters. * Other causes: The unit might be overcharged with refrigerant, so check the superheat/subcooling. A faulty HP switch could also be the culprit; check its continuity and operation, and replace if necessa...

Summary

General Information and Safety

Safety Warnings and Precautions

General safety warnings, cautions, and notices for operation and service.

Field Conversion of Air Discharge

Side to Back Discharge Conversion

Steps for converting the air discharge from side to back.

Back to Side Discharge Conversion

Instructions for converting discharge from back to side.

Horizontal Installation Details

Condensate Piping Installation

Instructions for installing condensate drain lines for horizontal units.

Duct System Installation Guidelines

Guidelines for proper duct system design and installation.

Vertical Installation

Condensate Piping for Vertical Units

Instructions for condensate piping for vertical units.

Piping Installation

Supply and Return Piping Installation

Guidelines for installing supply and return piping.

Water-Loop Heat Pump Applications

Commercial Water Loop Applications

Details for commercial systems using common piping.

Wiring Diagrams

CXM Board, ECM Fan Motor (Single Phase)

Wiring diagram for units with CXM board and ECM motor.

Units with ClimaDry (Single Phase)

Wiring diagram for units with ClimaDry® option.

CXM, ECM Motor, MPC (DDC) CONTROLS (Single Phase)

Wiring diagram for units with CXM, ECM, and MPC controls.

Control System Operation

Safety Features - CXM and DXM Controls

Protections against operation outside design conditions.

ClimaDry Modulating Reheat Option

Operation and components of the ClimaDry® reheat system.

Piping System Cleaning and Flushing

Unit and System Checkout

Unit Checkout Procedures

Pre-power checks for the unit, including valves, wiring, and fan.

System Checkout Procedures

Pre-power checks for the overall system, including water and controls.

Unit Start-Up Procedure

Preventive Maintenance

Functional Troubleshooting

Troubleshooting Main Power and HP Faults

Troubleshooting main power, HP fault codes, and low pressure issues.

Performance Troubleshooting

Insufficient Capacity Troubleshooting

Troubleshooting insufficient cooling or heating capacity.

High Head Pressure and Low Suction Pressure

Troubleshooting high head pressure and low suction pressure.

Warranty Information

U.S. & Canada Warranty

Details the limited express warranty terms and conditions for US & Canada.

International Warranty

Details the limited express warranty terms for international products.

ClimateMaster Tranquility TTD049 Series Specifications

General IconGeneral
BrandClimateMaster
ModelTranquility TTD049 Series
CategoryHeat Pump
LanguageEnglish