Tranquility
®
30
(TT) Series
Models TTD/H/V 026 - 072
60 Hz - HFC-410A
INSTALLATION, OPERATION,
& MAINTENANCE
97B0075N05
Revised: 18 July, 2013
Table of Contents
Model Nomenclature 3
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
Electrical - Line Voltage 20
Electrical - Power Wiring 22
Electrical - Power & Low Voltage Wiring 23
Electrical - Low Voltage Wiring 24
Electrical - Thermostat Wiring 26
Blower Performance Data 27
ECM Blower Control 28
Typical Wiring Diagram - Units with CXM Board
and ECM Fan Motor (Single Phase) 30
Typical Wiring Diagram - Units with
ClimaDry
®
(Single Phase) 31
Typical Wiring Diagram - Units with CXM Board, 32
ECM Fan Motor, and MPC (DDC) CONTROLS
(SINGLE PHASE) 32
CXM Controls 33
DXM Controls 34
Safety Features - CXM and DXM Controls 36
ClimaDry
®
Modulating Reheat Option 38
Unit Starting and Operating Conditions 41
Piping System Cleaning and Flushing 42
Unit and System Checkout 44
Unit Start-Up Procedure 45
ClimaDry
®
II Option Corrections
(When Operating in Non-ClimaDry
®
Mode) 46
Unit Operating Conditions 47
Preventive Maintenance 49
Functional Troubleshooting 50
Performance Troubleshooting 51
Start-Up Log Sheet 52
Functional Troubleshooting 53
Warranty (U.S. & Canada) 54
Warranty (International) 55
Revision History 56

Questions and Answers

  • C
    Cheryl MartinezAug 18, 2025
    How to troubleshoot main power problems in ClimateMaster Tranquility TTV049?
    • G
      Grant ChenAug 18, 2025
      If your ClimateMaster Heat Pump has main power problems and the Green Status LED is off, check the line voltage circuit breaker and disconnect. Also, check for line voltage between L1 and L2 on the contactor, for 24VAC between R and C on CXM/DXM, and the primary/secondary voltage on the transformer.
  • J
    jameswatsonAug 23, 2025
    Why does my ClimateMaster Heat Pump unit short cycle?
    • M
      marc59Aug 23, 2025
      If your ClimateMaster Heat Pump unit short cycles, it could be due to several reasons. A dirty air filter can cause short cycling, so check and clean it. Also, the unit might be in 'test mode'; reset the power or wait 20 minutes for it to automatically exit this mode. The unit might be oversized for the space; check the sizing for the actual load of the space. Finally, the compressor might be overloaded, so check it and replace it if necessary.
  • C
    chad61Aug 26, 2025
    Why does only the fan run on my ClimateMaster Tranquility TTV049?
    • N
      Nathan SmithAug 26, 2025
      If your ClimateMaster Heat Pump only runs the fan, it could be due to the following reasons: * Thermostat position: Ensure the thermostat is set for heating or cooling operation. * Unit lockout: Check for lockout codes and reset the power. * Compressor Overload: Check the compressor overload and replace it if necessary. * Thermostat wiring: Check the thermostat wiring at the heat pump. Jumper Y and R for compressor operation in test mode.
  • I
    Isaac TorresAug 28, 2025
    What does LP/LOC Fault Code 3 mean on my ClimateMaster Tranquility TTV049?
    • S
      smithstevenAug 28, 2025
      If your ClimateMaster Heat Pump is showing the LP/LOC Fault Code 3, indicating low pressure or loss of charge, it could be due to insufficient charge. Check for refrigerant leaks. Alternatively, the compressor might be pumping down at start-up, so check the charge and start-up water flow.
  • W
    William WarnerAug 31, 2025
    Why does only the compressor run on my ClimateMaster Tranquility TTV049?
    • J
      Julie BentleyAug 31, 2025
      If your ClimateMaster Heat Pump only runs the compressor, it could be due to the following issues: * Thermostat wiring: Check the G wiring at the heat pump. Jumper G and R for fan operation. * Fan motor relay: Jumper G and R for fan operation. Check for Line voltage across BR contacts. * Fan motor: Check for line voltage at the motor and check the capacitor. * Reversing valve: Set for cooling demand and check 24VAC on RV coil and at CXM/DXM board. If the RV is stuck, run high pressure up by reducing water flow and while operating engage and disengage RV coil voltage to push valve. * Thermostat setup: Check for ‘O’ RV setup not ‘B’. * Thermostat wiring: Check O wiring at heat pump. Jumper O and R for RV coil ‘click’.
  • D
    David PhillipsSep 2, 2025
    What does LT1 Fault Code 4 mean on my ClimateMaster Heat Pump?
    • C
      Carol GraySep 2, 2025
      If your ClimateMaster Heat Pump displays the LT1 Fault Code 4, which indicates a water coil low temperature limit, it could be due to: * Reduced or no water flow in heating: Check the pump operation or water valve operation/setting. Also, check water flow and adjust to proper flow rate. Clean or replace any plugged strainer or filter. * Inadequate antifreeze level: Check the antifreeze density with a hydrometer. * Improper temperature limit setting: Clip JW3 jumper for antifreeze (10°F [-12°C]) use. * Water temperature out of range: Bring the water temperature within design parameters. * Bad thermistor: Check the temperature and impedance correlation per chart.
  • G
    Gregory MuellerSep 4, 2025
    What does LT2 Fault Code 5 mean on my ClimateMaster Heat Pump?
    • W
      Willie RyanSep 4, 2025
      If your ClimateMaster Heat Pump displays the LT2 Fault Code 5, indicating an air coil low temperature limit, it may be caused by: * Reduced or no air flow in cooling: Check for a dirty air filter and clean or replace it. Also, check the fan motor operation and any air flow restrictions. Ensure that the external static isn't too high. * Air temperature out of range: Ensure that the entering air temperature is within design parameters. * Improper temperature limit setting: Normal airside applications will require 30°F [-1°C] only. * Bad thermistor: Check the temperature and impedance correlation per chart.
  • J
    jeffreynorrisSep 7, 2025
    What causes Condensate Fault Code 6 on my ClimateMaster Heat Pump?
    • J
      Jorge JosephSep 7, 2025
      If your ClimateMaster Heat Pump displays Condensate Fault Code 6, it could be due to several reasons: * Blocked drain: Check for blockage and clean the drain. * Improper trap: Check trap dimensions and location ahead of vent. * Poor drainage: Check for piping slope away from the unit and the slope of the unit toward the outlet. Also, check the vent location. * Moisture on sensor: Check for moisture shorting to the air coil. * Plugged air filter: Replace the air filter. * Restricted Return Air Flow: Find and eliminate the restriction. Increase return duct and/or grille size.
  • D
    Deborah MitchellSep 10, 2025
    What does Over/Under Voltage Code 7 mean on my ClimateMaster Heat Pump?
    • J
      Janice HarringtonSep 10, 2025
      If your ClimateMaster Heat Pump displays the Over/Under Voltage Code 7, which auto-resets, it indicates a voltage issue. For Under Voltage, check the power supply and 24VAC voltage before and during operation, the power supply wire size, and compressor starting (consider a hard start kit). Also, check the 24VAC and unit transformer tap for correct power supply voltage. For Over Voltage, check the power supply voltage and 24VAC before and during operation, and the 24VAC and unit transformer tap for correct power supply voltage.
  • J
    Jennifer HardinSep 12, 2025
    What does Unit Performance Sentinel Code 8 mean on ClimateMaster Tranquility TTV049?
    • A
      Anne MckaySep 12, 2025
      If your ClimateMaster Heat Pump displays Unit Performance Sentinel Code 8, it indicates a performance issue. If in heating mode and LT2 is greater than 125°F [52°C], check for poor air flow or an overcharged unit. If in cooling mode and LT1 is greater than 125°F [52°C] or LT2 is less than 40ºF [4ºC], check for poor water flow or air flow.

Summary

Model Nomenclature

General Information and Safety

Safety

Essential safety warnings and precautions for installation and service.

Pre-Installation Procedures

Pre-Installation

Steps and checks required before beginning unit installation.

Horizontal Installation

Vertical Installation

Piping Installation

Installation of Supply and Return Piping

Comprehensive guidelines for connecting supply and return piping to the unit.

Water-Loop Heat Pump Applications

Commercial Water Loop Applications

Details on applying heat pumps in commercial water loop systems, including flushing and flow rates.

Ground-Loop Heat Pump Applications

Water Quality Standards

Ground-Water Heat Pump Applications

Electrical - Line Voltage

Electrical - Power Wiring

Electrical - Power & Low Voltage Wiring

Electrical - Low Voltage Wiring

Electrical - Thermostat Wiring

ECM Blower Control

Typical Wiring Diagram - CXM;ECM (Single Phase)

Typical Wiring Diagram - ClimaDry (Single Phase)

Typical Wiring Diagram - CXM;MPC;DDC (Single Phase)

CXM Controls

DXM Controls

Safety Features - CXM and DXM Controls

Anti-short cycle protection

Protection against short cycling the compressor to prevent damage.

Fault Retry

How the control attempts to recover from faults, indicated by LED status.

Lockout

Control lockout mode, soft and hard reset procedures, and fault memory.

High pressure switch

Operation and effect of the high pressure switch on compressor operation.

Low pressure switch

How the low pressure switch is recognized as a fault after continuous open time.

Water coil low temperature (LT1)

LT1 fault condition and lockout based on water coil temperature limits.

Air coil low temperature (LT2)

LT2 fault condition and lockout based on air coil temperature limits.

Condensate overflow

Condensate overflow fault recognition and monitoring.

Over;under voltage shutdown

Safety shutdown due to voltage outside acceptable range, with self-resetting capability.

Safety Features - CXM and DXM Controls Continuation

Diagnostic Features

Using LEDs on CXM/DXM boards to diagnose control status and faults.

ClimaDry Modulating Reheat Option

ClimaDry Sequence Of Operation

How ClimaDry® operates in cooling, reheat, and heating modes with various thermostats.

UNIT STARTING AND OPERATING CONDITIONS

Unit Starting and Operating Conditions

Piping System Cleaning and Flushing

Piping System Cleaning and Flushing Procedures

Flushing;Purging Units with ClimaDry

Procedure for flushing and purging ClimaDry® coils, including valve operation.

Unit and System Checkout

Unit Checkout

Checklist of pre-power checks for unit components, wiring, and fan.

System Checkout

Checklist for system-level checks, including water temperature, pH, and controls.

Unit Start-Up Procedure

Unit Operating Conditions

Unit Operating Conditions Data

Preventive Maintenance

Water Coil Maintenance

Procedures for maintaining water coils in direct ground water and other water loop applications.

Filters

Importance of clean filters for performance and recommended maintenance schedule.

Functional Troubleshooting

Main power problems

Checks for issues related to main power supply, circuit breakers, and transformer.

HP Fault Code 2

Troubleshooting steps for High Pressure fault code 2, including refrigerant charge and switches.

High Pressure

Possible causes and solutions for high pressure conditions in the system.

LP;LOC Fault Code 3

Troubleshooting steps for Low Pressure/Loss of Charge fault code 3.

Low Pressure; Loss of Charge

Addressing low pressure or loss of charge issues in the system.

LT1 Fault Code 4

Troubleshooting steps for LT1 Fault Code 4 related to water coil low temperature.

LT2 Fault Code 5

Troubleshooting steps for LT2 Fault Code 5 related to air coil low temperature.

Condensate Fault Code 6

Troubleshooting steps for Condensate Fault Code 6 related to drainage issues.

Over;Under Voltage Code 7

Troubleshooting steps for Over/Under Voltage fault code 7.

Unit Performance Sentinel Code 8

Troubleshooting steps for Unit Performance Sentinel fault code 8.

Swapped Thermistor Code 9

Troubleshooting steps for Swapped Thermistor fault code 9.

Only Fan Runs

Troubleshooting when only the fan operates and the compressor does not.

Only Compressor Runs

Troubleshooting when only the compressor runs and the fan does not.

Unit Doesnt Operate in Cooling

Steps to take when the unit fails to operate in cooling mode.

Functional Troubleshooting Issues

Performance Troubleshooting

Addressing issues related to insufficient capacity or poor performance in heating/cooling.

Insufficient capacity

Diagnosing and resolving insufficient cooling or heating capacity issues.

High Head Pressure

Identifying causes and solutions for high head pressure conditions.

Functional Troubleshooting Analysis

ClimateMaster Tranquility TTV049 Series Specifications

General IconGeneral
BrandClimateMaster
ModelTranquility TTV049 Series
CategoryHeat Pump
LanguageEnglish