Tranquility
®
30
(TT) Series
Models TTD/H/V 026 - 072
60 Hz - HFC-410A
INSTALLATION, OPERATION,
& MAINTENANCE
97B0075N05
Revised: 18 July, 2013
Table of Contents
Model Nomenclature 3
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
Electrical - Line Voltage 20
Electrical - Power Wiring 22
Electrical - Power & Low Voltage Wiring 23
Electrical - Low Voltage Wiring 24
Electrical - Thermostat Wiring 26
Blower Performance Data 27
ECM Blower Control 28
Typical Wiring Diagram - Units with CXM Board
and ECM Fan Motor (Single Phase) 30
Typical Wiring Diagram - Units with
ClimaDry
®
(Single Phase) 31
Typical Wiring Diagram - Units with CXM Board, 32
ECM Fan Motor, and MPC (DDC) CONTROLS
(SINGLE PHASE) 32
CXM Controls 33
DXM Controls 34
Safety Features - CXM and DXM Controls 36
ClimaDry
®
Modulating Reheat Option 38
Unit Starting and Operating Conditions 41
Piping System Cleaning and Flushing 42
Unit and System Checkout 44
Unit Start-Up Procedure 45
ClimaDry
®
II Option Corrections
(When Operating in Non-ClimaDry
®
Mode) 46
Unit Operating Conditions 47
Preventive Maintenance 49
Functional Troubleshooting 50
Performance Troubleshooting 51
Start-Up Log Sheet 52
Functional Troubleshooting 53
Warranty (U.S. & Canada) 54
Warranty (International) 55
Revision History 56

Questions and Answers:

ClimateMaster Tranquility TTH064 Series Specifications

General IconGeneral
CategoryHeat Pump
RefrigerantR-410A
Compressor TypeScroll
TypeWater Source
ModelTranquility TTH064 Series

Summary

General Information and Safety

Safety Precautions and Warnings

Outlines DANGER, WARNING, CAUTION, and NOTICE classifications for safe operation.

Horizontal Unit Installation

Horizontal Unit Location Requirements

Guidelines for selecting an appropriate indoor location for horizontal units.

Horizontal Unit Mounting Procedures

Instructions for suspending units using hanger kits and vibration isolators.

Vertical Unit Installation

Supply and Return Piping Installation

Electrical - Line Voltage Wiring

Electrical - Power Wiring

Electrical - Low Voltage Wiring

CXM Controls Overview

CXM Control Operations

Overview of CXM control functions, test mode, and retry mode.

DXM Controls Overview

DXM Control Operations

Overview of DXM control functions, test mode, and retry mode.

CXM and DXM Control Safety Features

CXM/DXM Fault Retry and Lockout

How the control handles and signals faults, including soft and hard resets.

Low Pressure Switch Operation

Recognition criteria for low pressure faults and lockout conditions.

Water Coil Low Temperature Protection

Protection against freezing water coils using LT1 thermistor and cutout settings.

ClimaDry® Modulating Reheat Option

Unit Starting and Operating Conditions

Piping System Cleaning and Flushing

Piping System Cleaning and Flushing Procedure

Step-by-step procedure for cleaning and flushing the water loop piping system.

Unit and System Checkout

Unit Start-up Procedure

Unit Start-Up Procedure Steps

Step-by-step guide for initial unit operation, testing, and configuration.

Preventive Maintenance

Functional Troubleshooting

Troubleshooting Unit Faults

Common faults, possible causes, and solutions for unit operation issues.

Performance Troubleshooting

Troubleshooting Performance Issues

Diagnosing and resolving issues related to capacity, airflow, and efficiency.