Tranquility
®
30
(TT) Series
Models TTD/H/V 026 - 072
60 Hz - HFC-410A
INSTALLATION, OPERATION,
& MAINTENANCE
97B0075N05
Revised: 18 July, 2013
Table of Contents
Model Nomenclature 3
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
Electrical - Line Voltage 20
Electrical - Power Wiring 22
Electrical - Power & Low Voltage Wiring 23
Electrical - Low Voltage Wiring 24
Electrical - Thermostat Wiring 26
Blower Performance Data 27
ECM Blower Control 28
Typical Wiring Diagram - Units with CXM Board
and ECM Fan Motor (Single Phase) 30
Typical Wiring Diagram - Units with
ClimaDry
®
(Single Phase) 31
Typical Wiring Diagram - Units with CXM Board, 32
ECM Fan Motor, and MPC (DDC) CONTROLS
(SINGLE PHASE) 32
CXM Controls 33
DXM Controls 34
Safety Features - CXM and DXM Controls 36
ClimaDry
®
Modulating Reheat Option 38
Unit Starting and Operating Conditions 41
Piping System Cleaning and Flushing 42
Unit and System Checkout 44
Unit Start-Up Procedure 45
ClimaDry
®
II Option Corrections
(When Operating in Non-ClimaDry
®
Mode) 46
Unit Operating Conditions 47
Preventive Maintenance 49
Functional Troubleshooting 50
Performance Troubleshooting 51
Start-Up Log Sheet 52
Functional Troubleshooting 53
Warranty (U.S. & Canada) 54
Warranty (International) 55
Revision History 56

Questions and Answers

  • B
    Brian LewisSep 14, 2025
    What does Swapped Thermistor Code 9 mean on my ClimateMaster Tranquility TTV072?
    • J
      jonathan53Sep 14, 2025
      If your ClimateMaster Heat Pump displays Swapped Thermistor Code 9, it means that LT1 and LT2 thermistors are swapped. To resolve this, reverse the position of the thermistors.
  • L
    Lindsay AdamsNov 19, 2025
    What to do if my ClimateMaster Heat Pump shows HP Fault Code 2 High Pressure?
    • S
      Stephanie HarrisNov 19, 2025
      If your ClimateMaster Heat Pump displays the HP Fault Code 2 indicating high pressure, it could be due to several reasons: * Reduced or no water flow in cooling: Check pump or valve operation/setting and adjust the water flow to the proper rate. Also bring the water temperature within the design parameters. * Reduced or no air flow in heating: Inspect and clean or replace the air filter. Check the fan motor operation and look for air flow restrictions. Ensure the air coil is clean and the external static isn't too high. Also bring the return air temperature within design parameters. * Other causes: The unit might be overcharged with refrigerant, so check the superheat/subcooling. A faulty HP switch could also be the culprit; check its continuity and operation, and replace if necessa...

Summary

General Information and Safety

Critical Safety Warnings

Highlights DANGER, WARNING, CAUTION, and NOTICE statements for safe operation.

Horizontal Unit Installation

Vertical Unit Installation

Piping Installation

Water-Loop Heat Pump Applications

Ground-Loop Heat Pump Applications

Ground-Water Heat Pump Applications

Water Quality Standards

Provides standards for water quality to prevent scaling and corrosion.

Electrical - Line Voltage

Electrical - Power Wiring

Power Connection Guidelines

Explains connecting line voltage wires to the contactor and consulting data tables.

Electrical - Power & Low Voltage Wiring

Electrical - Low Voltage Wiring

Electrical - Thermostat Wiring

ECM Blower Control

Wiring Diagram: CXM & ECM Motor (Single Phase)

Wiring Diagram: ClimaDry (Single Phase)

Wiring Diagram: CXM, ECM, MPC (DDC)

CXM Control Operation

Field Configuration Options

Details jumper and DIP switch configurations for CXM control options.

DXM Controls

DXM Field Configuration Options

Details jumper and DIP switch configurations for DXM control options.

Safety Features - CXM and DXM Controls

Compressor Protection Features

Explains anti-short cycle, random start, and lockout protection.

Pressure and Temperature Limit Protection

Details high/low pressure, LT1/LT2 limits, and condensate overflow protection.

ClimaDry Modulating Reheat Option

ClimaDry Sequence Of Operation

Details the operating modes and thermostat compatibility for ClimaDry®.

UNIT STARTING AND OPERATING CONDITIONS

Operating Limits

Lists operating limits for air and water temperatures for optimal performance.

Unit Starting and Operating Conditions

Commissioning Conditions

Outlines commissioning limits for initial start-up and building conditioning.

Piping System Cleaning and Flushing

Piping System Cleaning and Flushing Procedure

Details the critical steps for cleaning and flushing the WLHP piping system.

Flushing;Purging Units with ClimaDry

ClimaDry Coil Flushing Procedure

Explains the process for flushing and purging the ClimaDry® hydronic circuit.

Unit and System Checkout

Unit Checkout Checklist

Lists essential checks for the unit before powering up the system.

System Checkout Checklist

Lists crucial checks for the overall system before powering up.

Unit Start-up Procedure

Cooling Mode Start-up

Guides through the start-up process for the cooling mode, including checks.

Heating Mode Start-up

Guides through the start-up process for the heating mode, including checks.

Unit Start-Up Procedure Details

Preventive Maintenance

Water Coil Maintenance

Guides on maintaining water coils based on water quality and loop type.

Filters Maintenance

Advises on inspecting, cleaning, and replacing air filters for optimal performance.

Condensate Drain Maintenance

Details cleaning and chemical treatment for condensate drains to prevent issues.

Compressor and Fan Motor Checks

Covers annual checks for compressor and fan motor amperage and condition.

Air Coil Cleaning

Guides on cleaning air coils and using surfactants for initial setup.

Functional Troubleshooting

Main Power and HP Fault Troubleshooting

Provides solutions for main power issues and HP fault code 2.

Low Pressure and High Pressure Troubleshooting

Guides on troubleshooting low/high pressure faults and lockout codes.

Temperature Limit and Condensate Faults

Covers troubleshooting LT1/LT2 faults and condensate drain issues.

Unit Operation Troubleshooting

Addresses issues like short cycling, fan-only operation, and unit not operating.

Performance Troubleshooting

Insufficient Capacity Troubleshooting

Helps diagnose and resolve issues causing insufficient cooling or heating capacity.

High Head Pressure Troubleshooting

Provides solutions for problems causing high head pressure in the system.

Low Suction Pressure Troubleshooting

Guides on identifying and fixing causes of low suction pressure.

Low Discharge Air Temperature in Heating

Helps troubleshoot low discharge air temperature issues during heating.

Functional Troubleshooting Analysis

Warranty (U.S. & Canada)

Limited Express Warranty Terms

Outlines the terms and conditions of the limited express warranty for North America.

Warranty Limitations and Exclusions

Specifies exclusions and limitations of the warranty coverage.

Warranty (International)

International Limited Express Warranty

Details the limited express warranty for products sold outside North America.

International Warranty Limitations

Lists exclusions and limitations applicable to international warranty claims.

ClimateMaster Tranquility TTV072 Series Specifications

General IconGeneral
CategoryHeat Pump
Cooling Capacity72, 000 BTU/h
RefrigerantR-410A
Compressor TypeScroll
ModelTTV072
Voltage208/230V