47
8.4.7.3 Breath Control
z Page 3 is for Breath Control Adjust
B r e a t h A d j u s t : 3
0 0 0:
When the breath controller is connected, use this function to adjust (calibrate) it.
By turning the gain and fine tune knobs in the breath controller, set the BC basic
value to 000, and set the data range to 000-127.
8.4.7.4 Local Control
z Page 4 is for local control
L o c a l : O n 4
The local control decides if the MIDI data will be sent to the expansion board.
Refer to the appendix <MIDI route>.
8.4.7.5 Pedal Type and Polarity
z Page 5 is for Pedal Type
P e d a l 1 : S w i t c h 5
P e d a l 2 : C o n t i n u
The pedal type of pedal1/2 can be Switch or continuous.
z Page 6 is for Pedal Polarity
P e d a l 1 :
6
P e d a l 2 :
Here you can switch the pedal polarity.
8.4.7.6 MIDI Filter
z Page 7 is for the MIDI Filter
C l o c k A c t i v e 7
O f f O f f
A f t e r t o u c h 8
O n
You can enable or disable the below MIDI messages for the instrument to send:
Clock: MIDI clock, by default it is disabled.
Active: MIDI active, by default it is disabled.
Aftertouch (page 8): Channel aftertouch, by default it is enabled.