Chapter 3: Troubleshooting
60 Status signaling
List of alerts
The list below shows the alerts that may appear in the display.
Responsibility transfer: The Radiotelex accepts responsibility transfer
requests for all category B Warnings via incoming NMEA command from
e.g. a CAM.
Escalation time: All Warnings are escalated as Warning after 4 minutes.
ID/
Instan-
ce
Prio-
rity
Cate-
gory
Title Description Reasons and remedy
3022/1 W B AC Power
Outage
AC power outage
has occurred.
Check AC power
distribution.
3023/6 C B PS Crosslink
ERR
Power supply
cross link error
Check power supply cross
link
3023/3 C B PS COMM
Lost
Power supply
communication
lost.
Check LAN-cable to SAILOR
6081 Power Supply Unit
and Charger. No
communication with the
power supply.
3065/1 W B INTERN
TEMP High
Internal power
supply tempera-
ture high
Check the power supply.
3023/1 C B BATT VOLT
Low
Battery and
charger. Voltage
below limit.
The battery voltage is
below the limit configured
for the SAILOR 6081 Power
Supply Unit and Charger.
3023/2 C B BATT VOLT
High
Battery and
charger. Voltage
above limit.
The battery voltage is
above the limit configured
for the SAILOR 6081 Power
Supply Unit and Charger.
3023/4 C B BATT TEMP
High
Battery
temperature
above limit
The battery temperature is
above the configured limit.