136
Chapter 5
Troubleshooting
5
Type in username and password.
Username: admin
Password: 1234
Welcome to the Thrane & Thrane shell
telnet:/$
To view the errorlog, use the cmd: errorlog
telnet:/$ errorlog
Error Log for Unit Serial number: 07441420
Error Log from previous power cycles
Version: 1.11, build Build-bganx_bdu_ak-16, UTC Wed Nov 11
07:29:52 2009
____________________________________________________
Error Log from current power cycle
Version: 1.11, build Build-bganx_bdu_ak-16, UTC Wed Nov 11
07:29:52 2009
____________________________________________________
telnet:/$
To delete the errorlog type: errorlog delete
telnet:/$ errorlog delete
Delete error log from FLASH
telnet:/$
5.8 Error log
debug:/$ errorlog
Error Log for Unit Serial number: 07441420
Error Log from previous power cycles
Version: 1.11, build Build-bganx_bdu_ak-16, UTC Wed Nov 11
07:29:52 2009
021:01:55.002 FATAL Thread: Alive UTC Tue Dec 29 09:00:01
2009
[pollTimeout, ld/build/source/p-bganx_bdu_ak/modules/
applications/bgan_ut/alive/src/alive.cpp line 97]:
ALIVE: Module ADU_MANAGER failed to answer poll request
SW Version: 1.11, build x_bdu_ak-16, UTC Wed Nov 11 07:29:52
2009 Prev. entry: 6 First
Figure 5-52
NOTE!
Help errorlog
Errorlog delete:
Delete error log in ram and
ash.
Errorlog noreboot:
Do not reboot on fatal error.
Errorlog stoptrace:
Do not add new trace lines
after a fatal error.
Errorlog allowreboot:
Allow reboot on fatal error.
Errorlog allowtrace:
Allow adding new trace lines
after a fatal error.
NOTE!
Search for:
Errorlog
Theerrorlogholdstherst50
fatal /non fatal events + the
events from the current power
cycle.
NOTE!
Fatal error when the antenna
fails to respond. Fatal error will
cause a reboot as the system
will try to recover.