page 32 of 45 GU-139-Z1
Command
Command
Command Explanation
Explanation
Explanation
Format
Format
Format
Default
Default
Default
90
92
95
96
97
98
99
76
77
78
Upon call in answer mode
PAS enable
Enable UPD on call answer
Programming password
Audio call password
Reset audio settings
Reset phone numbers only
Reset recordings only
Default all settings EXCEPT
audio, phone and recordings
Full reset (default ALL settings)
76<answer mode>#
77<pas>*<output(s)>*<recordings(s)>#
78<upd>#
90<new pass code>*<new pass code>#
92<new pass code>*<new pass code>#
95*95#
96*96#
97*97#
98*98#
99*99#
0
0#
0#
#
2583#
#
NOTES: FORMAT VALUE PARAMETERS
Command 77 = Public Address System
First Value Set, enabling PAS: 0 or 1
0 = disabled
1 = enabled
Second Value Set (outputs)
See Programming Outputs (page 26)
Third Value Set (recordings)
See Programming Messages (page 26)
Command 78 = Enable Unit Programming & Diagnostics (UPD): 0 or 1
0 = don’t send bit fault on answer menu instead of RFA
1 = send bit fault on answer menu instead of RFA
NOTES: FORMAT VALUE PARAMETERS
Command 76 = Answer mode: 0 or 1
0 = automatically enters two-way audio mode without password
1 = requires audio call password or phone will disconnect
NOTES: FORMAT VALUE PARAMETERS
Command 95 = Reset audio settings
Resets the audio gain for microphone, speaker, PAS and message volume back to default
**
Pass Codes and Reset Programming
IA4100
Administrator Guide
Code Blue
• 259 Hedcor Street • Holland, MI 49423 USA • 800.205.7186 • www.codeblue.com
Programming Commands (continued)