10.
PROCEDURE FOR CHANGING OIL ON HYDRAULIC STATION ON PR120H
During this operation it’s important to activate the emergency stop button!
Procedure step by step
1. Remove the oil. Drain out off this ball valve pos. 1. The used oil must be deposited at an approved
station for environmental waste.
2. Clean the hydraulic tank pos. 2 inside by removing the cover plate pos. 3 on the tank side.
3. Reassemble the hydraulic tank.
4. Put 85 liter “DTE MOBIL FM 32 approved for food manufacturing” in the hydraulic tank.
Notice:
If there are no demand for oil approved for food manufacturing, this oil can be used DTE MOBIL 24.
BEFORE STARTING PRODUCTION THE HYDRAULIC MOTION SHOULD BE CHECKED IN SINGLE MODE!
3. Cover plate
1. Ball valve
1. Hydraulic tank