R1000H
Alarmlist
Version: 2
Page: 1
Date: 07.11.2022
ALARM LIST
Use the alarm list and corresponding troubleshooting table for solving problems with the Cold Jet PR120H. When errors appear
comparing and identify it in the table below. Use table for troubleshooting to fix the error.
In general, Cold Jet recommend that the cause of errors is investigated as soon as they appear and that the machine is not being
operating until the error is identified or fixed. Some alarms are critical and can damage equipment if reset multiple times.
However, if the alarm is identified to not pose a threat to damage the machine, the alarm can be reset, and operation can continue
until spare parts etc. are available. If the error can’t be reset after remedy – Cold Jet recommend shutting down the machine and
leaving it without power for 5 minutes. If the error is still present and no troubleshooting in the manual fix the error, then please
contact Cold Jet Technical support.
Alarm no. Alarm text Troubleshooting no.
1
Error. Hardware E-Stop
3
2
Error. E-Stop active
3
3
Error. Build plug
37
4
Error. Max. time forward
38
5
Error. Max. time return
39
6
Error. Generel timeout
27
7
Error. Max. purge time exceeded
40
8
Error. Injection pressure exceeded
41
9
Error. Injection valve G01-Q1
4
10
Error. Feedback Injection valve G01-Q1
6
11
Error. SuperV Injection valve G01-Q1
26
12
Error. Both 1 and 2 Injection valve G01-Q1
1
13
Error. Both BG1 and BG2 Injection valve G01-Q1
2
14
Error. Max actiontime Injection valve G01-Q1
12
15
Error. Circuit breaker Injection valve G01-Q1
13
16
Error. Inverter Injection valve G01-Q1
11
17
Error. Hardware Injection valve G01-Q1
7
18
Error. Injection valve start-up G01-Q2
4
19
Error. Feedback Injection valve start-up G01-Q2
6
20
Error. SuperV Injection valve start-up G01-Q2
26
21
Error. Both 1 and 2 Injection valve start-up G01-Q2
1
22
Error. Both BG1 and BG2 Injection valve start-up G01-Q2
2
23
Error. Max actiontime Injection valve start-up G01-Q2
12
24
Error. Circuit breaker Injection valve start-up G01-Q2
13
25
Error. Inverter Injection valve start-up G01-Q2
11
26
Error. Hardware Injection valve start-up G01-Q2
7
27
Error. Valve degassing G01-Q5
4
28
Error. Feedback Valve degassing G01-Q5
6
29
Error. SuperV Valve degassing G01-Q5
26
30
Error. Both 1 and 2 Valve degassing G01-Q5
1
31
Fejl Both BG1 and BG2 Valve degassing G01-Q5
2
32
Error. Max actiontime Valve degassing G01-Q5
12
33
Error. Circuit breaker Valve degassing G01-Q5
13
34
Error. Inverter Valve degassing G01-Q5
11
35
Error. Hardware Valve degassing G01-Q5
7