Equipment Safety Features
Automatic Time Outs
Your spa is equipped with an automatic Time Out
feature designed to protect both the equipment and the
user. For your safety and to reduce unnecessary use of
the pumps and lights, the Time Out feature turns selected
accessories off automatically, as follows:
Common LCD Equipment Safety
Messages
The following table describes the most common
messages, possible causes, and corrective actions:
21
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
If the LCD
displays...
OHH
OHS
HFL
Indicates...
Overheat - one
of the sensors
has detected
water
temperature of
118
°
F+ inside
the heater
Overheat - One
sensor has
detected temper-
ature of spa
water entering
heater to be
110
°F
+
Heater flow
problem
What happens...
Spa heater will
automatically
shut down until
temperature falls
below 108
°F
Spa heater will
automatically
shut down until
temperature falls
below 108
°F
Heater will shut
down while spa
continues to
function normally
Corrective action...
- Make sure slice valves are open.
- Reprogram to ensure time
cycle not overlapping
- Contact dealer if problem persists
- Make sure slice valves are open
- Reprogram to ensure time
cycle not overlapping
- Contact dealer if problem
persists
- Remove filter and clean
- Add water
- Contact dealer or service person
Possible cause...
- Low speed pump operating
for an extended period of time
- Programming error causing
continuous filtering
- Pump failure
- Low speed pump operating
for an extended period of time
- Programming error causing
continuous filtering
- Plugged filer
- Low water
Accessory Mode Shuts off in...
Pump 1 Low 4 hours
Pump 2 Low 15 minutes
Pump 1 High 15 minutes
Pump 2 High 15 minutes
Blower 15 minutes
Light 1 hour
Digital Optic 1 hour