259720-CTG-B-0108
Unitary Products Group 7
Thermostat Chart - PSC Modulating Furnace/Single Stage Air Conditioner
AC 11D Single Stage Air Conditioner – PSC Modulating Furnace
FL9M
FC9M
PM9
ID MODELS
Part Numbers:
SAP = Legacy
155941 = 031-09140
1
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single Stage Compressor
PSC
MODULATING FURNACE
G
Fan
PSC
MODULATING
FURNACE
Y/Y2
Second or Full
Stage Compressor
1
W
Modulating Heat
C
24 – Volt Common
Y
Compressor
SINGLE STAGE
AIR CONDITIONER
SINGLE STAGE
AIR CONDITIONER
Y
Compressor Contactor
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
AIR CONDITIONER
C
24 – Volt Common
Y1
First Stage Compressor
L
Malfunction Light
Y2
Second Stage
Compressor
G
Fan
*PP32U71124
*PP32U72124
THERMOSTAT
R
24 – Volt Hot
W2
Second Stage Heat
DHM
Dehumidistat
HM
Humidistat
O
Reversing Valve
Energized in Cool
24VAC Humidifier
(Optional)
E/W1
First Stage Heat
Step 1 of the Thermostat
Installer Table must be
set to MTLI STG
E2/P Switch must be in the
E2 position
Step 5 of Thermostat User
Configuration Menu must
be set to “ON” for
Dehumidification

Related product manuals