DIL-switch DEL
This DIL-switch selects the mode of delayed predispensing. In this mode, the predis-
pensing is delayed, until the moment when the product has left the goods scanner's
position.
DIL-switch NS
This DIL-switch selects the Nonstopmode. In the Nonstopmode two Collamat
®
6600
can be used to work in a zero downtimemode. For further information to the Nonstop-
mode, please read the chapter Nonstopmode.
DIL-switch R1
This DIL-switch selects the function of the POSITION-potentiometer. Switched off the
potentiometer has the normal POSITION-function. Switched on, the potentiometer is
used to adjust a GSC1-suppression. The working range of the suppression then is the
same as in the POSITION-mode.
DIL-switch R2
This DIL-switch selects the working range of the potentiometers. For further informati-
ons, please read the chapter Testmode. The factory setting of the potentiometers is the
normal working range.
The function of the SPEED potentiometer can be changed in the testmode. If the
DIL-switch R2 is switched on, the potentiometer SPEED can be used to fineadjust the
steprate of an incremental encoder in the range of ±10 %. The speed is then measured
with an incremental encoder. See also chapter Testmode and Incremental encoder.
5999.527-01A 25.11.98 WM Seite 15 / 32