Manual FLOW 38 Page 37 (total 54) COMAC CAL s.r.o.
Volume units displayed [V]
To change the way of volumetric indication (+V, -V and ∑V), press E. The number of decimal
places for the volumetric counters can be selected from 3 to none. Furthermore, the selection of units is
here (L, m
3
). If these parameters are changed, the respective measured value will be changed as well. In
consequence, we recommend resetting of the counters changed in this way after reconfiguration.
User counter with reset option
It is the volumetric counter (rV) available to user who can reset it using external control buttons
(simultaneously and). The number of decimal places can be selected from 3 to none. Furthermore,
the selection of units is here (L, m
3
). If these parameters are changed, the respective measured value will
be changed in this counter as well the value is not recalculated. In consequence, we recommend
resetting of the counter changed in this way after reconfiguration.
Password change
The password for modification of the customer parameters is set by default to 0000. However,
the user can change it in this window by pressing E. The access code must have 4 digits.
Default settings (original factory settings)
During activation of this function, the configuration of the meter will be restored to the factory
default state in which it was shipped. All settings carried out by the user will be cancelled and all
volumetric counters will be reset.
The user password is cancelled and the access password is reset to original (0000).
At the same time, the calibration constants will be set to the factory values. Before activating this
function, it is useful to record or make a data backup of all counters.
m3
L
m3
L

Other manuals for COMAC CAL FLOW 38

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the COMAC CAL FLOW 38 and is the answer not in the manual?

COMAC CAL FLOW 38 Specifications

General IconGeneral
BrandCOMAC CAL
ModelFLOW 38
CategoryMeasuring Instruments
LanguageEnglish