16
AT THE END OF THE WORK
At the end of the work, and before carrying out any type of maintenance, perform the following
operations:
1. Turn off the solenoid valve switch (3)
2. Raise the squeegee by means of the rear handle
3. Turn off the suction switch (2)
4. Turn off the brush / main switch (1)
5. Raise the rear handle to lift up the squeegee
6. bring the machine to the place provided for draining the water
7. Remove the recovery tank, then remove the bayonet cap and tilt the tank to empty it
8. disassemble the brush and clean it with a jet of water (to disassemble the brush, see
DISASSEMBLING THE BRUSH below).
WARNING: this operation must be carried out wearing gloves to
protect against contact with dangerous solutions.