This setpoint is used for adjusting duration of the prelubrication cycle. See the 
output Prelubr pump for details about prelubrication. 
YES  
This setpoint is used for adjusting the pause between two consequent 
prelubrication cycles. See the output Prelubr pump for details about prelubrication. 
The setpoint adjusts the maximum duration the starter motor is energized within 
one cranking cycle. If there is none of running engine symptoms activated within 
this period the particular cranking attempt is finished and either a cranking pause 
follows or start fail alarm is issued. 
NOTE:  
At gas engines the last cranking cycle is extended about 25% and the engine is 
cranked with closed gas valve during this additional time to ventilate the remaining 
gas.  
 
NOTE:  
If magnetic pickup is used and the controller does not detect non-zero RPM within 
2s (gas engine) or 5s (diesel engine) after energizing the starter motor then 
cranking pause follows immediately (as the pinion is probably not properly 
engaged).  
 
NOTE:  
Learn more in the separate chapter Starting sequence.