4 Start and Stop engine
4.1 MANUAL mode
Green LED above AUTO button is off (controller is in MANUAL mode). When there is no any active
shut down alarm you can start the engine by pressing START button. Green LED above button will
blink. LED is blinking during starting, cooling or stopping procedure. When the engine is properly
started, the green LED will stop blink and start lights continuously. The generator is ready to load.
When you press START button again the GCB will close – only when the GCB is configured.
Press STOP button to stop the engine. First press will open the GCB and next press start cooling and
stopping procedure. When you press this button again the controller will stop the engine immediately.
For fast engine stop press and hold STOP button till engine stops.
4.2 AUTO mode
Green LED above AUTO button is on (controller is in AUTO mode). You can’t start the engine or
connect the load by pressing START button. The controller will start automatically when all conditions
for start and connecting load will be reached. The engine in AUTO mode can’t be stopped by pressing
STOP button.
Engine can be started or stopped via binary inputs I02 Remote Start/Stop or I03 Remote Start And
Load. For more details see InteliNano
NT
MRS 3 Reference Guide.