EasyManua.ls Logo

ComAp intelilite nt amf20

ComAp intelilite nt amf20
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Copyright © 2014 ComAp a.s.
Written by Petr Novák
Prague, Czech Republic
ComAp a.s.
Kundratka 2359/17, 180 00 Praha 8, Czech Republic
Tel: +420 246 012 111, Fax: +420 2 66316647
E-mail: info@comap.cz, www.comap.cz
Reference Guide
InteliLite
NT
InteliLite NT
AMF
Modular Gen-set Controller
Compact Controller for Stand-by Operating Gen-sets
(IL-NT AMF20/25 unit)
SW version 2.2, March 2016

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ComAp intelilite nt amf20 and is the answer not in the manual?

ComAp intelilite nt amf20 Specifications

General IconGeneral
Protection ClassIP20
Front Panel ProtectionIP65
Humidity95% non-condensing
DisplayLCD with backlight
Communication PortsRS232, RS485
Supported ProtocolsModbus RTU, Modbus TCP/IP
Digital Outputs4
Relay Outputs6

Summary

InteliLite NT AMF Modular Gen-set Controller

General Guidelines

Manual Purpose and Audience

Outlines the manual's scope, target users, and content overview.

Important Safety Instructions

Crucial safety advice for installation and maintenance procedures.

Warnings and Symbols Used

Key warnings and common symbols used throughout the document.

Software and Hardware Compatibility

Notes on compatibility between software and hardware versions.

General Description

Controller System Overview

Explains the InteliLiteNT AMF20/25 controller's features and capabilities.

Package Contents

Lists all accessories and modules included with the controller.

IL-NT RS232 Communication Plug-in Card

Installation Procedure

Step-by-step guide for installing the RS232 communication card.

IL-NT RS232-485 Communication Plug-in Card

IL-NT S-USB Service USB Communication Plug-in Card

IB-Lite Ethernet Communication Plug-in Card

IL-NT-GPRS GSM and GPRS Plug-in Modem

IL-NT AOUT8 Gauge Driver Module

IL-NT BIO8 Hybrid Binary InputOutput Module

IC-NT CT-BIO7 Interface Card

IL-NT RD Remote Display Software

Remote Annunciator IGL - RA15

IG IOMPTM Module

IG-IB Internet Bridge

InternetBridge-NT Module

IL-NT Terminals and Front Face

Controller Terminal Layout

Diagram showing controller terminals and their functions.

Front Panel Interface Description

Explanation of buttons, indicators, and display on the front panel.

Installation Procedures

Mounting Instructions

Guidelines for physically mounting the controller in an enclosure.

Dimensions and Cutout Specifications

Specifies physical dimensions and required panel cutout size.

Recommended Wiring Diagram

Shows essential wiring for AMF applications.

Stand-by Applications

Contactors and ATS Wiring Schemes

Wiring configurations for contactors and ATS systems.

Dual Mutual Standby (Dual AMF) Setup

Instructions for setting up two gen-sets in a mutual standby configuration.

Getting Started

Initial Installation and Setup

Covers controller installation, wiring, grounding, and power supply.

Binary Output Protections

Analog Input Signal Configuration

Magnetic Pick-up Input Setup

How to connect and configure the magnetic pick-up speed sensor.

Current Measurement (CTs)

Details on current transformer connections and CT location.

Analog Input Connection and Configuration

Setting up and connecting analog sensors for various measurements.

Communication Network Setup

CAN Bus and RS485 Connection Guidelines

Best practices for setting up CAN bus and RS485 networks.

Connecting Extension Modules via CAN Bus

CAN Bus Connection Rules

Rules for connecting modules via CAN bus.

Inputs and Outputs Overview

Binary Inputs Configuration

Details on default and programmable binary inputs.

Binary Outputs Configuration

Explains default and programmable binary outputs.

Setpoint Configuration Guide

Password Management and Basic Settings

Procedures for password setup and essential basic parameters.

Engine and Generator Parameter Settings

Configuration of engine and generator operating parameters.

Protection Settings (Engine and Generator)

Setup for engine and generator protection parameters.

AMF Application Settings

Configuration of Automatic Mains Failure functionality.

Communication and Remote Access Configuration

COM Port and Modem Settings

Settings for serial communication ports and modem connections.

Ethernet (IB-Lite) and GPRS (IL-NT-GPRS) Setup

Configuration for Ethernet and GPRS modules for remote access.

AirGate and Remote Messaging Setup

Setup for AirGate service and SMS/Email notifications.

Operating Modes and Sequences

OFF, MAN, and AUT Mode Operations

Detailed description of controller operating modes and their functions.

TEST Mode and Circuit Breaker Timing

How to use TEST mode and timing relationships for breakers.

Alarm Management

Alarm Types and Handling

Overview of available alarms and their management.

Gen-set Operation States and History

Engine states, conditions, and history file recording.

Init Screens and User Interface

Init Screens and Controller Information

Accessing controller information via Init Screens.

User Interface Customization

Options for selecting USER or ENGINEER interface.

Remote Control and Data Logging Tools

PC Software: LiteEdit

Using LiteEdit for configuration, monitoring, and data logging.

Remote Connection Methods

Direct cable, modem, and internet connection methods.

Modbus Protocol

Modbus Protocol Overview

Explanation of Modbus protocol selection and communication objects.

AMF25 Setpoint Communication List

Table mapping setpoints to Modbus communication objects.

Maintenance: Backup Battery Replacement

Technical Data

InputsOutputs Overview

Summary of controller's input and output capabilities.

Generator Protections (ANSI Codes)

List of generator protections with ANSI codes.

Power Supply and Operating Conditions

Electrical specifications and environmental operating limits.

Optional Modules and Interfaces Specifications

Technical details for optional communication and I/O modules.