3.5 EQUIPMENT CONNECTION
3.5.1 GROUNDING CONNECTION
Ground connection
To ensure safe operation of the product, a ground (earth) connection is required. For single phase AC
power source, the product must be grounded by connecting the “earth wire” of the power cord to the
ground terminal of the AC supply. For operating this product with DC power system (such as rectifiers),
the product should not be connected to power systems that switch open the return lead because the
return lead could function as the ground (earth) connection for the equipment.
Protective Ground Connection
The enclosure must be grounded securely by connecting a copper wire (CSA 16mm
2
) to the grounding
terminal on the equipment/rack, and the other end to a protective ground (i.e. building earth point). An
internationally acceptable colour code of the ground connection wire is green/yellow.
Such a ground connection implements the “Protective Ground Connection”, and must be connected to the
equipment at the designated ground point. In general, do not connect the supply before establishing an
adequate ground (earth) connection.
RA-7E00 Grounding Connection
The equipment must be grounded securely. Connect a copper wire to the grounding terminal on the
mounting tab/enclosure, and connect the other end to a protective ground (i.e. building earth point). An
internationally acceptable coloring code of the ground connection wire is green/yellow.
3.5.2 MU CONNECTION
3.5.2.1. MU connects with BTS
Connect MU with BTS by suitable RF jumper cables as shown in the following figure.