EasyManua.ls Logo

Comelit 4680C - De-misting Heating Element Configuration; Audio-Visual Message Configuration; Door Lock Control Configuration; Actuator Control Management

Comelit 4680C
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
CODE DIP SWITCH ON FUCNTION
De-misting heating element
213 1,3,5,7,8 OFF (default)
212 3,5,7,8 ON
Audio-visual messages
210 2,5,7,8 visual messages only
211 1,2,5,7,8 Swedish
214 2,3,5,7,8 OFF (default)
215 1,2,3,5,7,8 Italian
216 4,5,7,8 French
217 1,4,5,7,8 Spanish
218 2,4,5,7,8 Dutch
219 1,2,4,5,7,8 Greek
220 3,4,5,7,8 English
221 1,3,4,5,7,8 German
222 2,3,4,5,7,8 Portuguese
202 2,4,7,8 Enables voice message (door opened warning) when the RTE contact is closed
203 1,2,4,7,8
Disables voice message (door opened warning) when the RTE contact is closed (default
setting)
Door lock
223 1,2,3,4,5,7,8 Door lock command on SE in AC (default)
224 6,7,8 Door lock command on SE in enhanced AC
225 1,6,7,8 Door lock command on SE in DC
245 1,3,5,6,7,8 Door lock time: 2 sec + deactivation tone (default)
246 2,3,5,6,7,8 Door lock time: 4 sec
247 1,2,3,5,6,7,8 Door lock time: 8 sec
248 4,5,6,7,8 Door lock confirmation tone: enabled
251 1,2,4,5,6,7,8 C.NC.NO relay in parallel with SE (default)
252 3,4,5,6,7,8 Lock-release always enabled (default)
253 1,3,4,5,6,7,8 Lock-release only enabled for user called
Actuator control management
N.B. the system should not include Art. 1256 in generic actuator mode.
229 1,3,6,7,8 Enabling C.NC.NO relay on actuator control: 2 sec
230 2,3,6,7,8 Enabling C.NC.NO relay on actuator control: 4 sec
231 1,2,3,6,7,8 Enabling C.NC.NO relay on actuator control: 8 sec
228 3,6,7,8 Actuator control on serial line S: disabled (default)
227 1,2,6,7,8 Actuator control on serial line S: enabled
System functions
232 4,6,7,8 Awaiting response time: 60 sec (default)
233 1,4,6,7,8 Awaiting response time: 120 sec

Related product manuals