Do you have a question about the Comelit VEDO and is the answer not in the manual?
Brand | Comelit |
---|---|
Model | VEDO |
Category | Control Unit |
Language | English |
Details the function of each button on the keypad for system navigation and parameter entry.
Explains keypad signals like LCD screen and indicator LEDs.
Describes how to view system status on the keypad after user authentication.
Details the meanings of the keypad's 4 indicator LEDs and their status.
Provides a key to characters used on the second line to describe area status.
Step-by-step guide for performing a total activation of all enabled areas.
Procedure for deactivating system areas using the keypad.
Explains how to perform partial activations P1 and P2 using the keypad.
Details how to use function keys (F1-F4) for various system actions.
Describes how to activate the system quickly without entering a user code.
How to proceed with activation when zones are open.
Details how to proceed with activation when system faults are present.
Explains how to proceed with activation when tampering is detected.
Describes methods to lock an alarm in progress and stop calls.
Explains what happens when an invalid user code is entered.
Details the robbery code functionality and its use in duress situations.
Explains how to navigate the user menu and access options.
Details how to enter and modify numerical values for system parameters.
Explains the method for entering and modifying alphanumeric characters.
Step-by-step guide to performing a total system activation.
Procedure for deactivating the entire system.
How to activate pre-defined system scenarios.
Procedure for activating a single specific area of the system.
How to generate events configured for keypad keys 1 and 2.
Option to delay timed activation procedures.
Stops active alarms by deactivating outputs and blocking calls.
Resets alarm conditions, alarm memory, and ends ongoing calls.
Blocks ongoing calls and cancels queued calls.
Resets the control unit to its default settings.
Grants temporary access authorisation to the installer.
Enables manufacturer access for system updating purposes.
Procedure to test the system's input sensors.
Procedure to test system outputs and sirens.
Checks SIM card credit and GSM signal strength.
Measures the GSM signal strength for the SIM card.
Allows viewing zone statuses and performing actions like exclusion or activation.
Tools for editing and deleting user codes and managing access permissions.
How to set the system's date and time.
Enables or disables the control unit's voice menu functionality.
Permanently enables or disables the installer code without time limits.
Enables or disables timers for timed activation procedures.
Procedure for acquiring and registering new digital (RFID) keys.
Enables or disables a previously acquired digital key.
Edits the descriptive name associated with a digital key.
Deletes a previously acquired digital key from the system.
Edits the description for a telephone contact number.
Edits the telephone number for a contact in the phone book.
Edits the email address for a contact.
Enables receiving calls from a specific telephone number.
Enables receiving SMS alerts from a specific telephone number.
Enables receiving email alerts from a specific email address.
Enables receiving MMS alerts with images from a specific telephone number.
View all recorded system events.
View only alarm-related events.
Explains how to navigate the menus and use the touch screen interface.
Procedure for logging in using a user code or RFID key.
Describes the buzzer signals on the Vedo Touch device.
Describes the buttons used for activating/deactivating the system.
Explains the system status icon and its colour changes.
Procedure for performing system activations from the home screen.
Procedure for performing system deactivations from the home screen.
How to use RFID keys for activation and deactivation on the keypad.
Performing total activation using an RFID key.
Handling RFID key activation with open zones, faults, or tampering.
Performing total deactivation using an RFID key.
Selecting actions via RFID key without pressing buttons.
Explains the consequences of using invalid RFID keys.
View all recorded system events.
View only alarm-related events.
Available alarm types that can be assigned to function keys.
List of system commands executable via function keys or SMS.
Edits the description for a telephone contact number.
Edits the telephone number for a contact.
Edits the email address for a contact.
Enables receiving calls from a specific telephone number.
Enables receiving SMS alerts from a specific telephone number.
Enables receiving email alerts from a specific email address.
Enables receiving MMS alerts with images from a specific telephone number.
Accesses sub-menus for system configuration settings.
Edits the address/ID of the device on the BUS485.
Changes the communication speed for the BUS485 interface.
Changes the device password for product access.
Enters an optional user code for auto-configuration of parameters.
Edits network parameters and the IP address of the device.
Changes the IP address of the product.
Edits the subnet mask for network configuration.
Changes the gateway address for network connectivity.
Changes the ViP address of the product.
How to use RFID keys for activation and deactivation on the keypad.
Performing total activation using an RFID key.
Handling RFID key activation with open zones, faults, or tampering.
Performing total deactivation using an RFID key.
Selecting actions via RFID key without pressing buttons.
Explains the consequences of using invalid RFID keys.
Explains the status indications provided by the RFID reader.
Details LED meanings during standby, cycle, and key presentation.
Carrying out total activation using the RFID reader.
Handling RFID key activation when zones are open.
Carrying out total deactivation using the RFID reader.
Selecting actions via RFID reader by associating LEDs with actions.
Stopping an alarm in progress using the RFID reader.
Explains the indications provided by the radio control's LEDs.
How to perform system actions using the radio control buttons.
Configuring the signaller to send event alerts via telephone, SMS, Email, MMS.
How the system makes and handles telephone calls for alerts.
How the system sends and receives SMS alerts.
How the system sends and receives email alerts.
How the system sends MMS alerts with images from alarmed zones.
Steps to access and connect to the voice menu system.
Overview of the voice menu options for system status and management.
Function to get the status of the control unit, listing faults and tampering events.
Manage system areas, including status checks and activations/deactivations.
Activate a single area with different activation types.
Request the control unit's alarm log status via SMS.
Send the 'Stop alarm' command to the control unit via SMS.
Request the status of all control unit areas via SMS.
Activate or force activation of areas via SMS commands.
Deactivate specified areas via SMS commands.
Retrieve the status of specified zones via SMS.
Manage zones (include, exclude, activate, isolate) via SMS.
Retrieve the status of specified outputs via SMS.
Activate or deactivate specified outputs via SMS.
Request the remaining credit on the SIM card via SMS.
Accessing the web interface via a local network connection.
Accessing the web interface via a remote internet connection.
Explains the elements of the control unit web page interface.
Authorises the installer to log in to the system.
Authorises the manufacturer for system operations.
Updates control unit software and graphics skin.
Sets a dynamic DNS address for remote connection.