Last Trans. lev
Radio Zones
Last Trans. lev
Radio Outputs
Last Trans. lev
Radiocontrols
Lounge window
01 RSSI 80
IP Test
1 Entrance door
System Mgmt.
Syst. Analysis.
22
Radio RSSI test
This test can be used to measure the strength of the transmission signal between the control unit and the
radio zones, radio outputs and radio controls.
Using the arrow keys, select the category you wish to test from the following 3 options and press
ENTER’ to view the list of zones, outputs or radio controls available.
From the list (e.g. Radio Zones), select the input you wish to test and press ‘ENTER’.
The last RSSI value recorded by the control unit for that input is displayed.
The RSSI value shown is that obtained from the last communication between the radio expansion and the
radio device. To obtain the most recent information possible, we recommend opening or closing a zone,
activating or deactivating an output and pressing a key on the radio control.
RSSI values are classified in accordance with the following table:
0-30 Weak
30-70 Good
70-100 Excellent
We recommend installations are not carried out with values lower than 30.
System analysis
Zone status
This option allows you to view the status of the zones and perform actions on them, i.e. exclusion, inclusion,
activation or isolation.
Test progress is monitored via the following messages: “Timeout”, “In progress...”, “Requested...”,
“Error...”, “Ended”...
Use the arrow keys to scroll through the System Mgmt. menu to display:
MMS send test
When this test is carried out, an image is acquired by a camera connected to an input; this is sent via MMS
to the telephone number programmed in Safe Manager.
Using the up and down arrows, select an input from the list (only those with a camera connected) and
press ‘ENTER’ to start the test.
Generic event test
From this menu you can perform tests on all the programmed generic events. The pre-configured alerts for
the generic event are sent. The first generic event to be proposed is the "Call Test"; use the arrow keys to
scroll through the menu to select the generic event you wish to test.
Test progress is monitored via the following messages: “Timeout”, “In progress...”, “Requested...”,
“Error...”, “Ended”...