EasyManuals Logo

Comet KT 1750 extra User Manual

Comet KT 1750 extra
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16
MAINTENANCE INTERVAL OPERATION
Weekly Cleaning of inlet water lter
Unscrew the hose connector (12)
FIG. 7-a
and remove the lter(20)
FIG. 7-b
.
Cleaning the lter under running water or compressed air is generally
sucient. In more dicult cases, use a scale-removing product or
replace it by contacting an authorised assistance centre to purchase
it.
Ret the lter and tighten the hose connector.
Monthly Cleaning the nozzle.
It is usually sucient to clean the hole of the nozzle with the pin
supplied (17). If this operation fails to satisfactorily clean the nozzle,
replace the latter by ordering a spare part from an authorised service
centre.
The nozzle is replaced using the key (9) (supplied).
SUPPLEMENTARY MAINTENANCE
Supplementary maintenance must be carried out by a
QUALIFIED TECHNICIAN
, following the table below
(guideline data).
MAINTENANCE INTERVAL OPERATION
Every 50 hours Check the pump hydraulic circuit (water).
Check pump xing.
Every 100 hours Pump oil replacement.
Check pump delivery/intake valve.
Check tightness of pump screws.
Check pump control valve.
Check the safety devices.
PROBLEMS, CAUSES AND REMEDIES
PROBLEMS CAUSES REMEDIES
The high-pressure water
cleaner does not start when the
master switch (2) is place into
position“1”.
Please refer also to the
NOTE
in the paragraph “
STANDARD
OPERATION AT HIGH
PRESSURE
The safety device of the system
to which the high-pressure water
cleaner is connected has cut-in
(fuse, dierential switch, etc.).
Reset the safety device.
IF IT CUTSIN AGAIN, DO NOT
USE THE HIGHPRESSURE WATER
CLEANER AND CONTACT A
QUALIFIED TECHNICIAN.
Plug not connected correctly. Disconnect the plug and
reconnect it correctly.
The high-pressure water cleaner
vibrates a lot and is noisy.
Dirty water inlet lter (20) sporco. Follow that indicated in paragraph
“ROUTINE MAINTENANCE
.
Insucient water supply Make sure that the tap is
fully open and that the flow
rate of the mains water is in
accordance with that indicated
in paragraph
“TECHNICAL
CHARACTERISTICS AND
SPECIFICATIONS”
.
(continues on the next page)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Comet KT 1750 extra and is the answer not in the manual?

Comet KT 1750 extra Specifications

General IconGeneral
BrandComet
ModelKT 1750 extra
CategoryPressure Washer
LanguageEnglish

Related product manuals