Maintenance work to be completed every 48 months
52 A190-930TX_EN_03_ 2009-02-06
Remove used drying agent
Depressurise dryer and take out of service (see page 39).
Place suitable collection vessel underneath the drain point.
Use a suitable tool to remove the drain plug.
Drain drying agent into the collection vessel.
Use an industrial vacuum cleaner to hoover
up carefully the residues of the drying agent
via the drain plug aperture. In this way, you
also clean the sieve bottom at the same time
from any possible contamination or deposits.
Re-fix drain plug; as well renew the gasket.
Repeat the process on the second vessel.
Remove drain plug
Warning!
If the dryer is not used within specifications, the drying agent can be contami-
nated with pollutants. Always take this into account for the environmentally
safe disposal of the drying agent. The waste code numbers of the drying agent
can be obtained from the manufacturer (see page 6).
Dispose of the used drying agent in accordance with all applicable
regulations.
Fill with new drying agent
Risk of falls!
The dryer must not be misused as a climbing aid! The components have
not been designed for such loads and could fracture.
Only use approved climbing aids when filling the vessels.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CompAir A TX Series and is the answer not in the manual?

CompAir A TX Series Specifications

General IconGeneral
BrandCompAir
ModelA TX Series
CategoryDryer
LanguageEnglish

Related product manuals