3. Safety regulations
12
3.8 Dangers resulting from neglecting to perform maintenance
Danger
Safety measure required
Components of importance to safety
wear over time.
Observe the setting, maintenance, and inspection work and intervals
stipulated in the operating manual, including information about the
replacement of parts / partial sections. This work may only be carried out by
specialists.
Observe the intervals stipulated or those given in the operating manual for
routine checks and inspections.
Verify regularly that safety valves and other pressure-relief devices are in
perfect condition and are not blocked, for example by dirt or paint
Check regularly that the safety mechanisms are fully functional. Have
malfunctions corrected immediately.
Lines perish.
Check regularly that all hoses and/or pipes within the system are in good
condition, firmly fixed and do not chafe.
Spurting water can result in injuries.
Check all lines, hoses, and bolted connections regularly for leaks and visible
damage. Repair damage immediately and always arrange for damaged parts
to be replaced!
Risk of electric shock.
Have the electrical equipment on a machine/system checked regularly. Have
defects like loose connections or charred cables rectified immediately.
Use only original fuses with the specified current rating. In the event of faults
with the electrical power supply, switch the machine/system off immediately,
and secure it from being switched on again!
In the event of faulty sensors, the
system can be led into a dangerous
state of operation.
Check the accuracy of pressure and temperature indicators at regular
intervals. If the admissible tolerance limits have been exceeded, these
devices have to be replaced.
3.9 Dangers during maintenance and repairs
Danger
Safety measure required
During maintenance and repairs, parts
that may be pressurised must be
removed. If you maintain the
compressor and have not been trained
by CompAir, you will put yourself and
others at risk.
The compressor can only be maintained by specially trained technicians.
Contact your CompAir agent.
Incorrectly configured spare parts may
jeopardise safety, e.g. tear when loaded.
Spare parts must meet the technical requirements laid down by the
manufacturer. This is always guaranteed when original spare parts are used.

Table of Contents