10. Trouble-shooting
47
10 Trouble-shooting
No operating or control voltage
Check fuses, main switch and supply
line
Malfunction not acknowledged
Acknowledge fault message
Pressure reservoir not depressurized
Check connections, winding, etc.
Turn the compressor manually;
if required, replace
Ambient temperature less than
+1 °C/ 33.8 °F
Make sure that the ambient temperature
is not less than +1 °C/ 33.8 °F; install an
auxiliary heater, if required
Remote control has been activated via
terminal strip
Deactivate remote control/timer
Mains pressure is above the lower
switch set point
Wait until the mains pressure has fallen
below the lower switch set point
Unit stops during the
start-up phase
Intake regulator only closes partly,
pressure builds up too quickly in the
pressure reservoir
Fix intake regulator or, if required,
replace; check solenoid valves
Short-circuit in the unit
Determine and eliminate cause; replace
defective fuses
Connecting terminals in the switch
cabinet are loose
Select the type of oil according to the
ambient conditions or install an auxiliary
heater
Maximum motor switching cycles
exceeded due to too frequent manual
on and off-switching
Avoid frequent manual on and off-
switching, let electric motor cool down
Mains pressure sensor set too low
Unit does not reach the
set mains pressure
Intake regulator opens only partly
Fix intake regulator or, if required,
replace; check solenoid valves
Excessive air consumption
Reduce consumption or cut in a further
compressor
Replace fine separator cartridge
Replace air filter cartridge
Heavy leakage in the compressor
system
Mains pressure exceeds the lower
switching point
Wait until the mains pressure has fallen
below the lower switching point