Beeps: None (Beeps can be disabled by the user from the
Computer Setup utility.
Probable Cause: Disk 1 responded with an error
Recommended Action: 1. Run Computer Checkup (TEST).
2. Replace the drive.
3. Replace the system board.
---------------------------------------------------------------------------
Message: 1791 Disk 1 Error
Beeps: None (Beeps can be disabled by the user from the
Computer Setup utility.
Probable Cause: Hard Drive 1 Error
Recommended Action: 1. Run Computer Checkup (TEST).
2. Replace the drive.
3. Replace the system board.
---------------------------------------------------------------------------
Message: None
Beeps: 1 Short or 2 Short (Beeps can be disabled by the user
from the Computer Setup utility.
Probable Cause: Power on successful
Recommended Action: None
---------------------------------------------------------------------------
Message: None
Beeps: 1 Short or 2 Short (Beeps can be disabled by the user
from the Computer Setup utility.
Probable Cause: Resume= "F1" key as indicated to continue
Recommended Action: None
===========================================================================
Chapter 5.2 Diagnostic Error Codes
Diagnostic error codes occur if the system recognizes a problem while
running the Computer Checkup (TEST). These error codes help identify
possible defective subassemblies.
Tables 5-2 through 5-15 list possible error codes, a description of the
error condition, and the action required to resolve the error condition.
IMPORTANT: Retest the system after completing each step. If the problem has
been resolved, do not proceed with the remaining steps.
For assistance in the removal and replacement of a particular subassembly,
see Chapter 3, "Removal and Replacement Procedures."