Table 5-2. System Test Error Codes
===========================================================================
Error Code Description Recommended Action
===========================================================================
101 - xx CPU test failed Replace the system board and retest.
---------------------------------------------------------------------------
103 - xx DMA page registers test Replace the system board and retest.
failed
---------------------------------------------------------------------------
104 - xx Interrupt controller The following steps apply to
master test failed 104 - xx through 105 - xx error
codes:
105 - xx Port 61 error
Replace the system board and retest.
---------------------------------------------------------------------------
106 - xx Keyboard controller Replace the system board and retest.
self test failed
---------------------------------------------------------------------------
107 - xx CMOS RAM test The following steps apply to
failed 107 - xx through 113 - xx error
codes:
108 - xx CMOS interrupt test
failed Replace the system board and retest.
109 - xx CMOS clock load data
test failed
110 - xx Programmable timer
load data test failed
111 - xx Refresh detect test
failed
112 - xx Speed test slow mode
out of range
113 - xx Protected mode test
failed
---------------------------------------------------------------------------
114 - 01 Speaker test failed 1. Check system configuration.
2. Verify cable connections.
3. Replace the system board and
retest.
---------------------------------------------------------------------------
116 - xx Cache test failed Replace the system board and retest.
===========================================================================
Table 5-3. Memory Test Error Codes
===========================================================================
Error Code Description Recommended Action
===========================================================================
200 - xx Invalid memory Reinsert memory expansion board
configuration (Figure 5-1).
---------------------------------------------------------------------------
201 - xx Memory machine ID test The following steps apply to
failed 201 - xx through 202 - xx error
codes:
202 - xx Memory system ROM
checksum failed 1. Replace the memory expansion
board and retest (Figure 5-1).