12-5
Zone 3 – Logic Inputs – Switch Outputs
1. Logic Input #1 Enable
When this channel is enabled, a logic active high input on connector J3-1 will activate voice message #3.
This message is user programmable. The default message is “EMERGENCY POWER”.
2. Logic Input #2 Enable
When this channel is enabled, a logic high input on connector J3-2 will activate voice message #4. This
message is user programmable. The default message is “WEATHER ALERT”.
3. Logic Input #3 Enable
When this channel is enabled, a logic high input on connector J3-21 will activate voice message #5. This
message is user programmable. The default message is “INTRUDER ALERT”.
4. Logic Input #4 Enable
When this channel is enabled, a logic high input on connector J3-22 will activate voice message #6. This
message is user programmable. The default message is “HIGH TEMPERATURE”.
5. Switch #1 Enable
When this channel is enabled, switch #1 is turned on. Connector J3 pin 14 will sink 50 MA to ground.
6. Switch #2 Enable
When this channel is enabled, switch #2 is turned on. Connector J3 pin 15 will sink 50 MA to ground.
7. Switch #3 Enable
When this channel is enabled, switch #3 is turned on. Connector J3 pin 19 will sink 50 MA to ground.
8. Switch #4 Enable
When this channel is enabled, switch #4 is turned on. Connector J3 pin 20 will sink 50 MA to ground.