5. LOCATION OF THE THERMOSTAT
It is expedient to install the thermostat on the wall of a room
used regularly or for a prolonged stay, so that it is located in
the direction of natural air movement in the room, but do not
expose it to draughts of air or extreme heat e󰀨ects (e.g. solar
radiation, refrigerator or chimney). Its optimal position is at a
height of 1.5 m from the oor level.
The product has been designed so that it can be installed most
easily by sinking it in a 65 mm electric mounting box built in the
wall (Figure7).
IMPORTANTWARNING! If the radiator valves in your at are
equipped with thermostat head then set the thermostat head to
maximum level in the room where you intend to locate the room
thermostat or replace the thermostat head of the radiator valve
with manual regulating knob, otherwise the thermostat head
may disturb the temperature control in the at.
6. CONNECTION AND INSTALLATION OF
THE THERMOSTAT AND PUTTING IT
INTO OPER ATION
Attention! Makesurethatthe
COMPUTHERM
E280thermo-
stat and the apparatus to be controlled are de-energized