value (08) then the device will not return to default setting but
save the settings and exits the operation-related settings menu.
9. BASIC OPERATION OF THE THERMOSTAT
When it is switched on, on the basis of the temperature measured by
itself and currently set (manually or through programming), the ther-
mostat controls the apparatus(es) (e.g. gas boiler, pump) connected
thereto, considering the switch sensitivity of the thermostat (+/- 0.5°C).
This means that when the temperature is set to 22°C on the thermos-
tat then the relay outputs of the thermostat will close at temperatures
below 21.5°C (they give a switch-on command, i.e. they start the ap-
paratuses connected to the thermostat), while at temperatures above
22.5°C they will open (they give a switch-o󰀨 command, i.e. they stop
the apparatuses connected to the thermostat).
Attention! The accuracy of the temperature display on the thermos-
tat is 0.5°C, and the temperature values between integer and
half-integer values are shown in rounded gures. This may
lead to a situation where the output will not switch despite
a set temperature that is 0.5°C higher/lower than the tempe-
rature displayed, because the di󰀨erence between the actual
temperature and the set temperature is smaller than 0.5°C.
The relay outputs of the thermostat are open when the ther-

Table of Contents