11
On the main menu interface, short press the button to move the menu choice bar to "Power off", then
long press the button to shut down the device.
h
h
h
h
Exit
Exit
Exit
Exit
the
the
the
the
main
main
main
main
menu
menu
menu
menu
On the main menu interface,short press the button to move the menu choice bar to "Exit",then long
press the button to exit the main menu.
F.
F.
F.
F.
Charge
Charge
Charge
Charge
There are two kinds of charging methods:
a Connect the device with computer by data line, then the device should be under charging state.
b)
b)
b)
b)
C onnect the device with power supply by power adaptor, then the device should be under
charging state.
c)
c)
c)
c)
W hen the device is in the state of battering charging, the indication light appears to be orange,
and when the battery status is full, the light turns to green.
6.
6.
6.
6.
2
2
2
2
Attention
Attention
Attention
Attention
for
for
for
for
operation
operation
operation
operation
A. Please check the device before using, and confirm that
it
can work normally.
B
B
B
B
. The finger should be in a proper position (see the attached illustration of figure 4 for reference),
or else
it
may result in inaccurate measure.
C
C
C
C
. The SpO
2
sensor and photoelectric receiving tube should be arranged in a way with the subject
s
arteriole in a position there between .
D
D
D
D
. The SpO
2
sensor should not be used at a location or limb tied with arterial canal or blood
pressure cuff or receiving intravenous injection.
E
E
E
E
. Do not fix the SpO
2
sensor with adhesive or else
it
may result in venous pulsation and inaccurate
measure of SpO
2
a nd pulse rate .
F
F
F
F
. Excessive ambient light may affect the measuring result. It includes fluorescent lamp, dual ruby
light, infrared heater, direct sunlight and etc.
G
G
G
G
. Strenuous action of the subject or extreme electrosurgical interference may also affect the
accuracy.
H
H
H
H
. Testee can not use enamel or other makeup.
I
I
I
I
. Please clean and disinfect the device after operating according to the User Manual( 7 .1).
6
6
6
6
.3
.3
.3
.3
Clinical
Clinical
Clinical
Clinical
restrictions
restrictions
restrictions
restrictions
A. As the measure is taken on the basis of arteriole pulse, substantial pulsating blood flow of subject
is required. For a subject with weak pulse due to shock, low ambient/body temperature, major
bleeding, or use of vascular contracting drug, the SpO
2
waveform (PLETH) will decrease. In this case ,
the measurement will be more sensitive to interference.
B
B
B
B
. For those with a substantial amount of staining dilution drug (such as methylene blue, indigo
green and acid indigo blue), or carbon monoxide hemoglobin (COHb), or methionine (Me+Hb) or
thiosalicylic hemoglobin, and some with icterus problem, the SpO
2
determination by this monitor
may be inaccurate.
C
C
C
C
. The drugs like dopamine, procaine, prilocaine, lidocaine and butacaine may also be a major
factor blamed for serious error of SpO
2
measure.
D
D
D
D
. As the SpO
2
value serves as a reference value for judgement of anemic anoxia and toxic anoxia,

Other manuals for Contec CMS-50f

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contec CMS-50f and is the answer not in the manual?

Contec CMS-50f Specifications

General IconGeneral
BrandContec
ModelCMS-50f
CategoryMedical Equipment
LanguageEnglish

Related product manuals