Check the main unit and
all
accessories periodically to make sure that there is no visible damage
that may affect patient
s safety and monitoring performance about cables and transducers. It is
recommended that the device should be inspected once a week a t least. When there is obvious
damage, stop us ing the device.
Necessary maintenance must be performed by qualified service engineers
ONLY.
Users are not
permitted to maintain it by themselves.
The oximeter cannot be used together with devices not specified in User
s Manual. Only the
accessory that appointed or recommendatory by manufacture can be used with this device.
This product is calibrated before leav ing factory.
1.2
1.2
1.2
1.2
Warning
Warning
Warning
Warning
Explosive hazard DO NOT use the oximeter in environment with inflammable gas such as
some ignitable anesthetic agents.
DO NOT use the oximeter while the testee measured by MRI and CT.
Please do not break the wristband, for fear it becomes out of use, or the unexpected drop of the
device which is due to the looseness of the wristband in the process of using. U sers who are allergic
to the wristband is not recommended to use it.
The person who is allergic to rubber can not use this device.
The disposal of scrap instrument and its accessories and packings (including battery , plastic
bags, foams and paper boxes) should follow the local laws and regulations.
Please check the packing before use to make sure the device and accessories are totally in
accordance with the packing list, or else the device may have the possibility of working abnormally.
Please choose the accessories and probe which are approved or manufactured by the
manufacturer, or else it may damage the device.
The device can only be matched with the compatible probe.
Please don't measure this device with function test paper for the device's related information.
1.3
1.3
1.3
1.3
Attention
Attention
Attention
Attention
Keep the oximeter away from dust, vibration, corrosive substances, explosive materials, high
temperature and moisture.
If the oximeter gets wet, please stop operating it.
When it is carried from cold environment to warm or humid environment, please do not use it
immediately.
DO NOT operate keys on front panel with sharp materials.
High temperature or high pressure steam disinfection of the oximeter is not permitted. Refer to
User Manual in the relative chapter ( 7 .1) for instructions of cleaning and disinfection .
Do not have the oximeter immerged in liquid. When it needs cleaning, please wipe its surface
with medical alcohol by soft material. Do not spray any liquid on the device directly.
When cleaning the device with water, the temperature should be lower than 60 .
As to the fingers which are too thin or too cold, it would probably affect the normal measure of
the patients' SpO
2
and pulse rate, please clip the thick finger such as thumb and middle finger deeply

Other manuals for Contec CMS-50f

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contec CMS-50f and is the answer not in the manual?

Contec CMS-50f Specifications

General IconGeneral
BrandContec
ModelCMS-50f
CategoryMedical Equipment
LanguageEnglish

Related product manuals