11
d
d
d
d ) When charging the battery
in
the state of power off, the sign of battery status still exists on the
screen, but
it
will disappear
in
about 60 seconds for saving power. However, the sign will appear
again
if
you press any button(power on/off excluded) at this moment.
If
If
If
If the
the
the
the alarm
alarm
alarm
alarm function
function
function
function is
is
is
is on
on
on
on ,
,
,
, the
the
the
the device
device
device
device will
will
will
will provide
provide
provide
provide high-priority
high-priority
high-priority
high-priority alarm
alarm
alarm
alarm signal
signal
signal
signal when
when
when
when the
the
the
the
battery
battery
battery
battery is
is
is
is in
in
in
in low
low
low
low power
power
power
power status
status
status
status .Intermittent
.Intermittent
.Intermittent
.Intermittent alarm
alarm
alarm
alarm will
will
will
will occur
occur
occur
occur and
and
and
and the
the
the
the battery
battery
battery
battery icon
icon
icon
icon turns
turns
turns
turns red
red
red
red in
in
in
in
the
the
the
the state
state
state
state of
of
of
of flashing.
flashing.
flashing.
flashing.
High
High
High
High priority
priority
priority
priority indicating
indicating
indicating
indicating that
that
that
that immediate
immediate
immediate
immediate operator
operator
operator
operator response
response
response
response is
is
is
is required.
required.
required.
required.
6.2
6.2
6.2
6.2 Attention
Attention
Attention
Attention for
for
for
for operation
operation
operation
operation
A.
A.
A.
A. Please check the device before using, and confirm that
it
can work normally.
B
B
B
B . The finger should be
in
a proper position (see the attached illustration of figure 3 for reference), or
else
it
may result
in
inaccurate measure.
C.
C.
C.
C. The SpO
2
sensor and photoelectric receiving tube should be arranged
in
a way with the subject
’
s arteriole
in
a position there between .
D
D
D
D .
.
.
. The SpO
2
sensor should not be used at a location or limb tied with arterial canal or blood pressure
cuff or receiving intravenous injection.
E
E
E
E .
.
.
. Do not fix the SpO
2
sensor with adhesive or else
it
may result
in
venous pulsation and inaccurate
measure of SpO
2
a nd pulse rate .
F
F
F
F
.
.
.
. Excessive ambient light may affect the measuring result. It includes fluorescent lamp, dual ruby
light, infrared heater, direct sunlight and etc.
G
G
G
G
.
.
.
. Strenuous action of the subject or extreme electrosurgical interference may also affect the
accuracy.
H
H
H
H
.
.
.
. Testee can not use enamel or other makeup.
I
I
I
I .
.
.
. Please clean and disinfect the device after operating according to the User Manual(7.1).
6.3
6.3
6.3
6.3 Clinical
Clinical
Clinical
Clinical restrictions
restrictions
restrictions
restrictions
A.
A.
A.
A. As the measure is taken on the basis of arteriole pulse, substantial pulsating blood flow of
subject is required. For a subject with weak pulse due to shock, low ambient/body temperature,
major bleeding, or use of vascular contracting drug, the SpO
2
waveform (PLETH) will decrease. In
this case, the measurement will be more sensitive to interference.
B
B
B
B .
.
.
. For those with a substantial amount of staining dilution drug (such as methylene blue, indigo
green and acid indigo blue), or carbon monoxide hemoglobin (COHb), or methionine (Me+Hb) or
Power supply by battery only, and battery status is full
Battery status is not full
Battery status is draining away
Low power alarm indication ( Please cha r ge the battery )
the four status above shows
dynamically
in
turn
Battery is under charging