6
5.
5.
5.
5. 4
4
4
4 Accessories
Accessories
Accessories
Accessories
A.
A.
A.
A.
A
lithium battery Model: GSP053759, rated voltage
3.7V,
capacity1050mAh)
B.
B.
B.
B.
A
User Manual
C.
C.
C.
C.
A
power adapter
D.
D.
D.
D.
A
data line
E.
E.
E.
E.
A
disk (PC software)
F.
F.
F.
F.
An adult- oximeter probe Model:CMS-03
An
infant-oximeter probe ( May purchase selectively)
6
6
6
6 Operating
Operating
Operating
Operating Guide
Guide
Guide
Guide
6.1
6.1
6.1
6.1 Application
Application
Application
Application method
method
method
method
A.
A.
A.
A.
a)
a)
a)
a) Open the
lid
of battery box and put the battery
in
side , then close.
b)
b)
b)
b) Put the suitable probe into the jack on the right side of the oximeter. (The probe is limited to be
produced by our company; never re place
it
with the similar ones by other manufacturers ).
c)
c)
c)
c) Put the finger into the probe .
d)
d)
d)
d) Press the "power on/off button" long about a few seconds,the power is on,and the device will
start to self-inspect .The device displays the measuring interface after self-inspect ing.
e)
e)
e)
e) Do not shake the finger and keep the patient
in
a stable state during the process.
f)
f)
f)
f) The data can be read directly from the screen on the measuring interface.
Fingernails
Fingernails
Fingernails
Fingernails and
and
and
and the
the
the
the luminescent
luminescent
luminescent
luminescent tube
tube
tube
tube should
should
should
should be
be
be
be on
on
on
on the
the
the
the same
same
same
same side.
side.
side.
side.
If
If
If
If the
the
the
the alarm
alarm
alarm
alarm function
function
function
function is
is
is
is on
on
on
on ,
,
,
, the
the
the
the device
device
device
device will
will
will
will provide
provide
provide
provide midium-priority
midium-priority
midium-priority
midium-priority alarm
alarm
alarm
alarm signal
signal
signal
signal when
when
when
when
probe
probe
probe
probe or
or
or
or finger
finger
finger
finger is
is
is
is out
out
out
out I
I
I
I ntermittent
ntermittent
ntermittent
ntermittent alarm
alarm
alarm
alarm will
will
will
will occur
occur
occur
occur and
and
and
and the
the
the
the user
user
user
user interface
interface
interface
interface presents
presents
presents
presents
"FINGER
"FINGER
"FINGER
"FINGER OUT".
OUT".
OUT".
OUT".
Medium
Medium
Medium
Medium priority
priority
priority
priority indicating
indicating
indicating
indicating that
that
that
that prompt
prompt
prompt
prompt operator
operator
operator
operator response
response
response
response is
is
is
is required.
required.
required.
required.
Figure 5
Actual probe may be different with the probe as figure 5,please accept the actual probe with the
device

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contec CMS60C and is the answer not in the manual?

Contec CMS60C Specifications

General IconGeneral
BrandContec
ModelCMS60C
CategoryMedical Equipment
LanguageEnglish