7
B.
B.
B.
B. Change
Change
Change
Change display
display
display
display direction:
direction:
direction:
direction:
On the measuring interface, press the"screen change button"can change the display direction.
C.
C.
C.
C. Pause
Pause
Pause
Pause alarm:
alarm:
alarm:
alarm:
a)
a)
a)
a) Alarm including the alarm of measure data's going beyond the limits, the alarm of low-voltage,
the alarm of probe or finger's out of position.
b)
b)
b)
b) When alarm is on,press the"alarm pause button"can pause the alarm,it can renew alarm
in
about
60s,and
if
pressing the"alarm pause button" Again with
in
60s,it can renew alarm .
c)
c)
c)
c) If you want to turn off the alarm for good, you should enter the menu for operation.
D.
D.
D.
D. Menu
Menu
Menu
Menu operations:
operations:
operations:
operations:
On the measuring interface,press the"menu button"can enter the menu of figure 6.Users can adjust
the setting through the main menu, such as alarm, pulse sound indication, backlight,data storage,data
transmission (with the use of data line),the specific method is as follows:
Figure 6. Main Menu Interface
a)
a)
a)
a) Alarm
Alarm
Alarm
Alarm setting
setting
setting
setting
On the main menu interface,press the"up button"or"down button",move the menu choice bar to
"
Alarm
"
,then press the"menu button"to enter the alarm setting menu of figure
7:
Figure 7. Alarm Setting Menu
a.
a.
a.
a. The
The
The
The highest/lowest
highest/lowest
highest/lowest
highest/lowest alarm
alarm
alarm
alarm limit
limit
limit
limit setting
setting
setting
setting
Press the"up button"or"down button" to choose the parameter to be adjusted , then press the"menu
button"again to enter the similar dialog box shown as figure 8,then press the"up button"or"down
button"to change data. Each p ress of the"up button"or"down button" , the data will raise or descend
for one time accordingly , until
it
gets to the required number , then press the "menu button"for
another time to end the set ting .
If
If
If
If the
the
the
the alarm
alarm
alarm
alarm function
function
function
function is
is
is
is on
on
on
on ,
,
,
, the
the
the
the device
device
device
device will
will
will
will provide
provide
provide
provide midium-priority
midium-priority
midium-priority
midium-priority alarm
alarm
alarm
alarm signal
signal
signal
signal when
when
when
when the
the
the
the
data
data
data
data of
of
of
of SpO
SpO
SpO
SpO
2
2
2
2
or
or
or
or pulse
pulse
pulse
pulse rate
rate
rate
rate is
is
is
is beyond
beyond
beyond
beyond the
the
the
the limit.
limit.
limit.
limit. Intermittent
Intermittent
Intermittent
Intermittent alarm
alarm
alarm
alarm will
will
will
will occur
occur
occur
occur and
and
and
and the
the
the
the