Edition 07/2008 - XEOS EVOLUTION 2 - XEOS TALL CUP
NOTES TECHNIQUES - TECHNICAL DOCUMENTS - page 51
SACOME, Document CONFIDENTIEL,
Ne peut être reproduit ni communiqué sans notre accord préalable.
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
FAULT CAUSE SOLUTION
11
Certain coffee operations are
not working correctly.
Check:
Keyboard/Main circuit board
Check electrical
connections on each group.
Change the circuit keyboard
12
Steam leaking from the
pressure relief valve 1,5 bars.
1. Overheating - the boiler is
overpressure - the manometer
needle indicates a pressure of
over 22 PSI.
2. The pressure relief valve.
1. Check if the pressure switch is
working : adjust/replace
2. Change the pressure relief valve
1,5 bars