Electrical connected load ratings
The following table shows the electrical installed load ratings:
OES
6.06 mini 6.10 mini 10.10 mini
Table-top appliances
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption [kW] 5,7 7,1 10,5
Convection power [kW] 5,4 6,8 10,2
Motor power [kW] 0,25 0,25 0,25
Rated current [A] 11,8 14,8 15,7
Fuse [A] 16 16 20
recommended conductor
cross-section*
[mm
2
] 5G2.5 5G2.5 5G2.5
Heat output
latent [kJ/h] 1000 1330 1850
sensible [kJ/h] 1100 1450 2030
*recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.
Appliance technical standards
The following table shows the technical standards for the appliance:
OES mini 6.06 mini 6.10 mini 10.10 mini
Table-top appliances
Degree of protection IPX4
Approval mark*
TÜV/GS, DIN GOST TÜV, SVGW
Noise emission
measured [dBA] < 60