Design and function
minis user manual 18
Water connection
The following table shows the values for the water supply:
OES mini 6.06 mini 6.10 mini 10.10 mini
Table-top appliances
Water supply (cold only)
Shut-off valve
with non-return valve (type EA) and dirt filter
Water supply
without CONVOClean
system
1 x G 3/4'', permanent connection recommended
with CONVOClean
system
1 x G 3/4'', permanent connection recommended
Flow pressure
without CONVOClean
system
[kPa]
200 - 600 (2 - 6 bar)
with CONVOClean
system
[kPa]
300 - 600 (3 - 6 bar)
Water drain*
Type
DN
40 40 40
* Permanent connection (recommended) or funnel waste trap
Water quality
The following table shows the values for the water quality:
OES mini Table-top appliances
Injection, condenser, cleaning
Drinking water quality (install water treatment unit if necessary)
Total hardness
(German degrees of
hardness)
[°dH] 4 - 7
(French degrees of
hardness)
[TH] 7 - 13
(English degrees of
hardness)
[°e] 5 - 9
[ppm] 70 - 125
[mmol/l] 0,7 - 1,3
temperature (T) [°C] max. 40
conductivity [µS/cm] min. 20
pH 6,5 - 8,5
Cl- [mg/]l max. 100
SO
4
2-
[mg/l] max. 150
Fe [mg/l] max. 0.1