Moving and setting up the appliance
Installation manual 32
Note on setting up table-top appliances:
Make sure that your work surface or oven stand is able to bear the relevant appliance weight (includ-
ing the maximum permissible load).
Minimum vertical clearance above the appliance
The following points must be taken into account for the minimum vertical clearance above the appli-
ance:
The minimum vertical clearance depends on:
the type of gas flue system and
the nature of the ceiling.
Gas appliances can reach temperatures of up to 400°C.
The following table shows the values for the minimum vertical clearance above:
Appliance type minimum vertical clearance above
Electric appliances [mm] 500
Gas appliances [mm] 1000
Minimum distance from heat sources
Heat sources must be kept at a minimum distance (a) of 500 mm from the appliance, as shown in the
following diagram:
a