Connecting up the combi steamer
Installation manual 67
Gas appliance under an extractor hood
The combi steamer can be installed under a fume extractor hood.
In this case, a safety device in the ventilation system must ensure that the gas supply to the burner is
only allowed to flow when the extraction system is running.
The following diagram shows the combi steamer beneath the fume extractor hood:
Gas appliance under a ceiling fitted with ventilation equipment (option)
Combi steamers fitted with a draught diverter (type B13 gas appliance, special accessory) can be
fitted under a ceiling containing ventilation equipment.
In this case, a safety device in the ventilation system must ensure that the gas supply to the burner is
only allowed to flow when the extraction system is running.
The following diagram shows the combi steamer beneath a ceiling fitted with ventilation equipment:
Gas appliance connected directly to a flue
Combi steamers fitted with a draught diverter (type B13 gas appliance, special accessory) can be
connected directly to the flue.
Follow the steps below to connect your combi steamer to the flue:
Step Action
1 Use an approved registered chimney sweep to clean the connecting pipe to the flue system. Ensure
you obtain a record of this work.
2
Secure the appliance mechanically to prevent movement.
3
The gas flue pipes must be sealed and fitted in accordance with local and national regulations.
4