EasyManua.ls Logo

COOLIUS A10 - Download the Service Report

COOLIUS A10
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15COOLIUS A10 / Y10
4 Maintenance
4.1 Filter and vacuum pump oil replacement
4.1.1 Replacing the lter
NOTE: Always use goggles and gloves!
Contact with the refrigerant can cause blindness and other physical injury to
the user!
1. Beforedismountingthelter,performarecoveryprocessinordertoreducethepressureintheinternal
circuit!
IMPORTANT: Disconnect the plug from the power supply!
2. Remove the front cover.
3. Using a 38 mm wrench
2
unscrewthelter
1
.
NOTE: Dispose according to local
regulations.
4. Lubricate and place correctly the new O-rings.
5. Assemblethenewlter.
6. Reassemble the front cover.
g.001 Filter replacement
1
2

Other manuals for COOLIUS A10

Related product manuals