4 Maintenance
4.1 Filter and vacuum pump oil replacement
4.1.1 Replacing the lter
NOTE: Always use goggles and gloves!
Contact with the refrigerant can cause blindness and other physical injury to
the user!
1. Beforedismountingthelter,performarecoveryprocessinordertoreducethepressureintheinternal
circuit!
IMPORTANT: Disconnect the plug from the power supply!
2. Remove the front cover.
3. Using a 38 mm wrench
2
unscrewthelter
1
.
NOTE: Dispose according to local
regulations.
4. Lubricate and place correctly the new O-rings.
5. Assemblethenewlter.
6. Reassemble the front cover.
g.001 Filter replacement
1