M750 and M800 Installation Instructions 15
1515
15
• LED3 (network 2 fuse) – Same as LED2, but for
network 2.
• LED4 (PSTN) – Illuminates when there is activity on
the PSTN port (M800 only).
• LED5 (power) – Illuminates when the panel is
energised (either from the AC input or from the
battery).
• LED6 (12V output fuse) – Monitors the polyfuse
protecting the 12Vdc output from the terminal
block labelled "16" on Figure 2.
• LED7 (Bell output fuse) – Monitors the polyfuse
protecting the bell output labelled "9" on Figure 2.
• LED8 (relay 1 status) – Illuminates when relay 1 is
energised.
• LED9 (relay 2 status) – Not used.
• LED10 (transistor output 3 status) – Illuminates
when transistor output 3 is active.
• LED11 (transistor output 4 status) – Illuminates
when transistor output 4 is active.
• LED12 (strobe output status) – Illuminates when the
strobe output is active.
• LED13 (bell output status) – Illuminates when the
bell output is active.
• LED14 (transistor output 5 status) – Not used.
Polyfuses
The PCB contains the following automatically-
resettable polyfuses. Note that to reset a polyfuse, the
load must be removed completely.
• F1 – Battery load circuit (the on-board circuit that
periodically monitors the health of the battery).
• F2 – Network 1 12Vdc output.
• F3 – Network 2 12Vdc output.
• F4 – Extension loudspeaker.
• F5 – 12Vdc output from the 12V terminals on the
terminal block labelled "16" on Figure 2.
• F6 – Bell output from terminal 4 on the terminal
block labelled "9" on Figure 2.
Electromagnetic Compatibility
When used as intended this product complies with
EMC Directive (89 /336 /EEC). Any modifications other
than those stated in this manual, or any other use of
this product may cause interference and it is the
responsibility of the installer to comply with the EMC
and Low Voltage Directives.
Technical Specifications
Environmental Class 2
Security EN50131-1 or PD6662 Grade 1, 2
or 3. See page 14.
Mains Supply: 145mA @ 230Vac±10%, 50Hz
PCB Power Supply: 13.65VDC, 1.5A
A maximum of 750mA is
available for the control panel
PCB and other devices (excluding
battery recharge)
Standby Battery: 12VDC, lead-acid.
See page 14 for further details.
Charging limit: 750mA
Recharge time: 24 hrs max. for 17AH battery
Zones: 8 on-board zones, expandable
to 40
Network 1: Max of 4 keypads/LEC2s
Network 2: Max of 3 XNodes/MNodes or
keypads/LEC2s, or one ID Node
Additional ports: Engineer's keypad port
USB port to PC
Printer (RS232) port
PSTN/RJ11 for phone connection
(M800 only)
Output module port
Relay Outputs: 1 voltage-free changeover
1A max @ 24Vac or 24Vdc
Transistor Outputs: 1 Switched -ve @500mA
1 Switched +ve @500mA
Digi Outputs 1-16: Source 5mA in 12V condition
Sink 100mA in 0V condition
Selectable output sense
REN Value: 0.2
Speaker Output: 16 Ohms
Bell Trigger: Switched -ve @500mA
Strobe Trigger: Switched -ve @500mA
Mains Input Fuse: 315mA (Slow)
Dimensions: 384(W), 312(H), 95(D) mm
Material: 1.2mm mild steel
Weight: 4.9 Kg
Environment: -10 to 40°C
Humidity 0 to 75% RH, non-condensing.
Standards: EN 50131-1, PD 6662, TS 50131,
BS4737, EN 50130.
This equipment is compliant with EN 50136-2-1 & EN 50136-2-2. It
allows the alarm transmission system to meet the performance
requirements of prEN50131-1: 2004 ATS 2 provided that:
a) It is installed in accordance with the installation instructions.
b) The connected PSTN is functioning normally.
c) The ARC is adequately equipped.