vii
166240001
ICE CUBER SPECIFICATION – 60 HERTZ
MODEL IRC630 IRC830
IRC1030
IRC1030L
IRC1230
UNIT
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
No. Wires 2+ground 2+ground 2+ground 2+ground
MIN. CIRCUIT
Amps 20 20 20 20
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps 20 20 20 20
REFRIGERANT
Type R404a(HP62) R404a(HP62) R404a(HP62) R404a(HP62)
Weight (oz) 170 170 210 210
Weight (g) 4820 4820 5954 5954
COMPRESSOR
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
LRA 69 61 82 96
RLA 8.8 12.5 13.0 13.5
CONDENSER FAN MOTOR (AIR COOLED SYSTEMS ONLY
AIR CIRCULATION FAN MOTOR (WATER-COOLED & REMOTE SYSTEMS ONLY)
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
Amps Running 0.36 0.36 0.36 0.36
Watts 6 6 6W 6
WATER PUMP
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
Amps Running 0.5 0.5 0.5 0.5
HP 1/30 1/30 1/30 1/30